[{"name":"R5-206075","title":"On DFF QoQZ MU","source":"Keysight Technologies UK Ltd","contact":"Thorsten Hertel","contact-id":77978,"tdoctype":"discussion","for":"Endorsement","abstract":"This contribution is presenting DFF QoQZ MU for 2 AoA RRM.\nThe following observations and proposals were made in this contribution\nProposal 1: Set the MU element of Quality of Quiet Zone for FR2_A, FR2_B, and FR2_C to 1.1dB or 1.3dB for Stage 2 depending on whether the re-positioning concept is used as a baseline for MTSU and to 0.3dB for Stage 1 for 2 AoA RRM test cases based on the DFF implementation\nProposal 2: Set the MU element of Quality of Quiet Zone for FR2_A, FR2_B, and FR2_C for 1 AoA RRM test cases to the same values as for the 2 AoA RRM test cases based on the DFF implementation.\nProposal 3: For validation test ranges FR2_A, FR2_B, and FR2_C, define the \u201cInfluence of XPD\u201d MU for DFF to be 0.03dB.","secretary_remarks":"","agenda_item_sort_order":93,"ainumber":"5.3.2.17","ainame":"\tDiscussion Papers \/ Work Plan \/ TC lists","tdoc_agenda_sort_order":60750,"status":"revised","reservation_date":"2020-10-30 14:43:10","uploaded":"2020-10-31 00:28:34","revisionof":"","revisedto":"R5-206608","release":"","crspec":"","crspecversion":"","workitem":[{"winame":"5GS_NR_LTE-UEConTest"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG5_Test_ex-T1\/TSGR5_89_Electronic\/Docs\/R5-206075.zip","group":"R5","meeting":"R5-89-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0}]