[{"name":"R5-193444","title":"Agreement of noise impact during RAN5 NR#5 AdHoc","source":"Anritsu, ROHDE & SCHWARZ, Keysight Technologies UK Ltd","contact":"Ingbert Sigovich","contact-id":28887,"tdoctype":"discussion","for":"Discussion","abstract":"In RAN5 NR#5 AdHoc, documents [1] \u2013 [3] are discussed and following agreements are made: [..]\nProposal 1 : For MOP (TRP, PC3) FR2a, ?SNR=0.1dB, Relaxation=0dB for IFF 30cm and 15cm\nProposal 2 : For MOP (TRP, PC3) FR2b, ?SNR=0.3dB, Relaxation=0dB for IFF 30cm and 15cm\nProposal 3 : For SEM(TRP, PC3) FR2a, ?SNR=0.62dB, Relaxation=0dB for IFF 30cm and 15cm\nObservation 1 : For OFF Power, test cannot be carried out without relaxation. Required relaxation is in the range 28 - 42.7dB for FR2a 400MHz BW if threshold SNR is 10dB for IFF 30cm and 15cm\nObservation 2 : For OFF Power, test cannot be carried out without relaxation. Required relaxation is in the range 35 \u2013 45.9dB for FR2b 400MHz BW if threshold SNR is 10dB for IFF 30cm and 15cm","secretary_remarks":"","agenda_item_sort_order":18,"ainumber":"4.1.6","ainame":"\tTS 38.521-3","tdoc_agenda_sort_order":344400,"status":"noted","reservation_date":"2019-04-15 13:37:35","uploaded":"2019-04-15 13:37:57","revisionof":"","revisedto":"","release":"","crspec":"","crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG5_Test_ex-T1\/TSGR5_AHs\/2019-04-08_5G-NR_Adhoc_5\/Docs\/R5-193444.zip","group":"R5","meeting":"R5-ah-35450","year":2019,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0}]