[{"name":"R4-2008282","title":"Remove power-class ambiguity for UL-MIMO PC2 capable UE configured for EN-DC","source":"Qualcomm Incorporated","contact":"Ville Vintola","contact-id":84577,"tdoctype":"CR","for":"Agreement","abstract":"The power-class indication for the NR CG is ambigous for a UE indicating PC2 and supporting two SRS ports in SA but only one SRS port in NSA. When configured for EN-DC a UE is allowed to comply with NR PC3 (if implemented with two PC3 TX-chains) or NR PC2 (if implented with at least one PC2 TX-chain). This ambiguity can be removed if the former UE implementation indicates PC3 for NR SA, the minimum power capability for any transmission.","secretary_remarks":"","agenda_item_sort_order":14,"ainumber":"4.4.2.1","ainame":"Power class related to UL MIMO and other related req. (MPR, SEM, etc) [NR_newRAT-Core]","tdoc_agenda_sort_order":1620,"status":"not pursued","reservation_date":"2020-05-15 23:52:39","uploaded":"2020-05-15 23:55:41","revisionof":"","revisedto":"","release":"Rel-15","crspec":"38.101-3","crspecversion":"15.9.0","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":293.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_95_e\/Docs\/R4-2008282.zip","group":"R4","meeting":"R4-ah-38108","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0}]