[{"name":"S2-2407735","title":"Handling of Access Types for the EPC IWK case for maximum number of UE","source":"Ericsson","contact":"Shabnam Sultana","contact-id":21207,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Add the behvaior when operator policy considered the AccessType over which the PDU Session\/PDN connection is received in NSACF for counting purposes, and when operator policy did not consider for counting puprposes in NSACF the Access Type.","secretary_remarks":"Merged into S2-2408732","agenda_item_sort_order":108,"ainumber":"9.36","ainame":"Enhancement of NSAC for maximum number of UEs with at least one PDU session\/PDN connection (eNSAC)","tdoc_agenda_sort_order":15720,"status":"merged","reservation_date":"2024-07-08 12:53:03","uploaded":"2024-08-09 21:25:19","revisionof":"","revisedto":"","release":"Rel-18","crspec":"23.502","crspecversion":"18.6.0","workitem":[{"winame":"eNSAC"}],"crnumber":4873.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_164_Maastricht_2024-08\/Docs\/S2-2407735.zip","group":"S2","meeting":"S2-164","year":2024,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"4.11.5.9a","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2408284","title":"Clarification on Access Type for UE counting","source":"ZTE, Samsung","contact":"Jinguo Zhu","contact-id":32987,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Add clarification on how the local policy is configured for UE counting according to the Access Type.","secretary_remarks":"Revised in parallel session to S2-2408732, merging S2-2407735","agenda_item_sort_order":108,"ainumber":"9.36","ainame":"Enhancement of NSAC for maximum number of UEs with at least one PDU session\/PDN connection (eNSAC)","tdoc_agenda_sort_order":15730,"status":"revised","reservation_date":"2024-09-08 08:39:08","uploaded":"2024-08-09 14:05:27","revisionof":"","revisedto":"S2-2408732","release":"Rel-18","crspec":"23.502","crspecversion":"18.6.0","workitem":[{"winame":"eNSAC"}],"crnumber":4949.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_164_Maastricht_2024-08\/Docs\/S2-2408284.zip","group":"S2","meeting":"S2-164","year":2024,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"4.11.5.9a","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2408285","title":"Clarification on Access Type for UE counting","source":"ZTE, Samsung","contact":"Jinguo Zhu","contact-id":32987,"tdoctype":"CR","for":"Approval","abstract":"Rel-19 mirror CR: Summary of change: Add clarification on how the local policy is configured for UE counting according to the Access Type.","secretary_remarks":"Revised in parallel session to S2-2408733, merging S2-2408489","agenda_item_sort_order":108,"ainumber":"9.36","ainame":"Enhancement of NSAC for maximum number of UEs with at least one PDU session\/PDN connection (eNSAC)","tdoc_agenda_sort_order":15760,"status":"revised","reservation_date":"2024-09-08 08:39:09","uploaded":"2024-08-09 14:05:27","revisionof":"","revisedto":"S2-2408733","release":"Rel-19","crspec":"23.502","crspecversion":"19.0.0","workitem":[{"winame":"eNSAC"}],"crnumber":4950.0,"crrevision":"","crcategory":"A","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_164_Maastricht_2024-08\/Docs\/S2-2408285.zip","group":"S2","meeting":"S2-164","year":2024,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"4.11.5.9a","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2408481","title":"Clarifications on Option 2 NSAC for maximum number of UEs with at least one PDU SessionPDN Connection","source":"Samsung, Nokia","contact":"Ashok Kumar Nayak","contact-id":90702,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: 1) Delete the text 'As an optimization option, the SMF+PGW-C can be configured not to trigger the Nnsacf_NSAC_NumOfUEsUpdate_Request to NSACF'","secretary_remarks":"Noted in parallel session","agenda_item_sort_order":108,"ainumber":"9.36","ainame":"Enhancement of NSAC for maximum number of UEs with at least one PDU session\/PDN connection (eNSAC)","tdoc_agenda_sort_order":15790,"status":"noted","reservation_date":"2024-09-08 13:54:15","uploaded":"2024-08-09 13:57:11","revisionof":"","revisedto":"","release":"Rel-18","crspec":"23.501","crspecversion":"18.6.0","workitem":[{"winame":"eNSAC"}],"crnumber":5589.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_164_Maastricht_2024-08\/Docs\/S2-2408481.zip","group":"S2","meeting":"S2-164","year":2024,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.15.11.5a","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2408489","title":"Handling of Access Types for the EPC IWK case for maximum number of UE","source":"Ericsson","contact":"Shabnam Sultana","contact-id":21207,"tdoctype":"CR","for":"Approval","abstract":"Rel-19 mirror CR: Summary of change: Add the behvaior when operator policy considered the AccessType over which the PDU Session\/PDN connection is received in NSACF for counting purposes, and when operator policy did not consider for counting puprposes in NSACF the Access Type.","secretary_remarks":"","agenda_item_sort_order":108,"ainumber":"9.36","ainame":"Enhancement of NSAC for maximum number of UEs with at least one PDU session\/PDN connection (eNSAC)","tdoc_agenda_sort_order":13030,"status":"available","reservation_date":"2024-09-08 14:19:40","uploaded":"2024-08-09 21:25:19","revisionof":"","revisedto":"","release":"Rel-19","crspec":"23.502","crspecversion":"19.0.0","workitem":[{"winame":"eNSAC"}],"crnumber":4972.0,"crrevision":"","crcategory":"A","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_164_Maastricht_2024-08\/Docs\/S2-2408489.zip","group":"S2","meeting":"S2-164","year":2024,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"4.11.5.9a","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2408732","title":"Clarification on Access Type for UE counting","source":"ZTE, Samsung","contact":"Jinguo Zhu","contact-id":32987,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Add clarification on how the local policy is configured for UE counting according to the Access Type.","secretary_remarks":"Revision of S2-2408284, merging S2-2407735. Revised in parallel session to S2-2409045.","agenda_item_sort_order":108,"ainumber":"9.36","ainame":"Enhancement of NSAC for maximum number of UEs with at least one PDU session\/PDN connection (eNSAC)","tdoc_agenda_sort_order":15740,"status":"revised","reservation_date":"2024-08-25 18:30:23","uploaded":"2024-08-25 18:31:07","revisionof":"S2-2408284","revisedto":"S2-2409045","release":"Rel-18","crspec":"23.502","crspecversion":"18.6.0","workitem":[{"winame":"eNSAC"}],"crnumber":4949.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_164_Maastricht_2024-08\/Docs\/S2-2408732.zip","group":"S2","meeting":"S2-164","year":2024,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"4.11.5.9a","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2408733","title":"Clarification on Access Type for UE counting","source":"ZTE, Samsung","contact":"Jinguo Zhu","contact-id":32987,"tdoctype":"CR","for":"Approval","abstract":"Rel-19 mirror CR: Summary of change: Add clarification on how the local policy is configured for UE counting according to the Access Type.","secretary_remarks":"Revision of S2-2408285, merging S2-2408489. Revised in parallel session to S2-2409046.","agenda_item_sort_order":108,"ainumber":"9.36","ainame":"Enhancement of NSAC for maximum number of UEs with at least one PDU session\/PDN connection (eNSAC)","tdoc_agenda_sort_order":15770,"status":"revised","reservation_date":"2024-08-25 18:30:24","uploaded":"2024-08-25 18:31:07","revisionof":"S2-2408285","revisedto":"S2-2409046","release":"Rel-19","crspec":"23.502","crspecversion":"19.0.0","workitem":[{"winame":"eNSAC"}],"crnumber":4950.0,"crrevision":1.0,"crcategory":"A","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_164_Maastricht_2024-08\/Docs\/S2-2408733.zip","group":"S2","meeting":"S2-164","year":2024,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2409045","title":"Clarification on Access Type for UE counting","source":"ZTE, Samsung","contact":"Jinguo Zhu","contact-id":32987,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Add clarification on how the local policy is configured for UE counting according to the Access Type.","secretary_remarks":"Revision of S2-2408732. Agreed in parallel session","agenda_item_sort_order":108,"ainumber":"9.36","ainame":"Enhancement of NSAC for maximum number of UEs with at least one PDU session\/PDN connection (eNSAC)","tdoc_agenda_sort_order":15770,"status":"agreed","reservation_date":"2024-08-25 18:33:42","uploaded":"2024-08-25 18:41:09","revisionof":"S2-2408732","revisedto":"","release":"Rel-18","crspec":"23.502","crspecversion":"18.6.0","workitem":[{"winame":"eNSAC"}],"crnumber":4949.0,"crrevision":2.0,"crcategory":"F","tsg_crp":"SP-241245","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_164_Maastricht_2024-08\/Docs\/S2-2409045.zip","group":"S2","meeting":"S2-164","year":2024,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2409046","title":"Clarification on Access Type for UE counting","source":"ZTE, Samsung","contact":"Jinguo Zhu","contact-id":32987,"tdoctype":"CR","for":"Approval","abstract":"Rel-19 mirror CR: Summary of change: Add clarification on how the local policy is configured for UE counting according to the Access Type.","secretary_remarks":"Revision of S2-2408733. Agreed in parallel session","agenda_item_sort_order":108,"ainumber":"9.36","ainame":"Enhancement of NSAC for maximum number of UEs with at least one PDU session\/PDN connection (eNSAC)","tdoc_agenda_sort_order":15800,"status":"agreed","reservation_date":"2024-08-25 18:33:43","uploaded":"2024-08-25 18:41:09","revisionof":"S2-2408733","revisedto":"","release":"Rel-19","crspec":"23.502","crspecversion":"19.0.0","workitem":[{"winame":"eNSAC"}],"crnumber":4950.0,"crrevision":2.0,"crcategory":"A","tsg_crp":"SP-241245","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_164_Maastricht_2024-08\/Docs\/S2-2409046.zip","group":"S2","meeting":"S2-164","year":2024,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0}]