[{"name":"R4-1812269","title":"Discussion on EIRP OFF power for measuring FR2 transient period","source":"CATT","contact":"Yuexia Song","contact-id":34261,"tdoctype":"discussion","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":316,"ainumber":"7.9.4.3.3.1","ainame":"FR2 transient time test and OFF powerNR_newRAT-Perf]","tdoc_agenda_sort_order":253400,"status":"noted","reservation_date":"2018-09-27 10:00:55","uploaded":"2018-09-29 10:28:01","revisionof":"","revisedto":"","release":"Rel-15","crspec":"38.141-2","crspecversion":"","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812269.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812534","title":"Further discussion on FR2 OTA TDD transient time","source":"ZTE Corporation","contact":"Fei Xue","contact-id":59676,"tdoctype":"other","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":316,"ainumber":"7.9.4.3.3.1","ainame":"FR2 transient time test and OFF powerNR_newRAT-Perf]","tdoc_agenda_sort_order":254500,"status":"noted","reservation_date":"2018-09-28 07:26:53","uploaded":"2018-09-28 11:28:00","revisionof":"","revisedto":"","release":"","crspec":"","crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812534.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812545","title":"TP to TS 38.141-2:  transient period (6.5.2)","source":"ZTE Corporation","contact":"Fei Xue","contact-id":59676,"tdoctype":"pCR","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":316,"ainumber":"7.9.4.3.3.1","ainame":"FR2 transient time test and OFF powerNR_newRAT-Perf]","tdoc_agenda_sort_order":324300,"status":"noted","reservation_date":"2018-09-28 07:32:20","uploaded":"2018-09-28 11:28:00","revisionof":"","revisedto":"","release":"Rel-15","crspec":"38.141-2","crspecversion":"1.0.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812545.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812551","title":"Further discussion on FR2 OTA TDD transient time","source":"CMCC","contact":"Ningyu Chen","contact-id":62843,"tdoctype":"discussion","for":"Discussion","abstract":"","secretary_remarks":"","agenda_item_sort_order":316,"ainumber":"7.9.4.3.3.1","ainame":"FR2 transient time test and OFF powerNR_newRAT-Perf]","tdoc_agenda_sort_order":255100,"status":"noted","reservation_date":"2018-09-28 07:32:37","uploaded":"2018-09-28 09:59:39","revisionof":"","revisedto":"","release":"","crspec":"","crspecversion":"","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812551.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812685","title":"Discussion on on\/off mask test","source":"Huawei, HiSilicon","contact":"Xiang (Steven) Chen","contact-id":41576,"tdoctype":"other","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":316,"ainumber":"7.9.4.3.3.1","ainame":"FR2 transient time test and OFF powerNR_newRAT-Perf]","tdoc_agenda_sort_order":268500,"status":"noted","reservation_date":"2018-09-28 09:29:21","uploaded":"2018-09-28 15:25:04","revisionof":"","revisedto":"","release":"","crspec":"","crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812685.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812893","title":"On FR2 OTA transmit ON\/OFF power test aspects","source":"Ericsson","contact":"Torbjorn Elfstrom","contact-id":44796,"tdoctype":"discussion","for":"Discussion","abstract":"In an agreed way-forward document [1] guidance for this meeting was captured. In this contribution we present some further aspects to consider if EIRP is selected as the parameter for conformance testing.","secretary_remarks":"","agenda_item_sort_order":316,"ainumber":"7.9.4.3.3.1","ainame":"FR2 transient time test and OFF powerNR_newRAT-Perf]","tdoc_agenda_sort_order":289300,"status":"noted","reservation_date":"2018-09-28 12:10:51","uploaded":"2018-09-28 14:24:04","revisionof":"","revisedto":"","release":"Rel-15","crspec":"","crspecversion":"","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812893.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812920","title":"Tx transient time test in FR2","source":"Nokia, Nokia Shanghai Bell","contact":"Toni Lahteensuo","contact-id":82478,"tdoctype":"other","for":"Discussion","abstract":"In this contribution one possibility for transient time measurement procedure utilizing EIRP is presented.","secretary_remarks":"","agenda_item_sort_order":316,"ainumber":"7.9.4.3.3.1","ainame":"FR2 transient time test and OFF powerNR_newRAT-Perf]","tdoc_agenda_sort_order":289500,"status":"noted","reservation_date":"2018-09-28 12:15:44","uploaded":"2018-09-28 17:02:04","revisionof":"","revisedto":"","release":"","crspec":"","crspecversion":"","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812920.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812923","title":"TP to TS 38.141-2: Corrections on OTA transmit ON\/OFF power","source":"Nokia, Nokia Shanghai Bell","contact":"Toni Lahteensuo","contact-id":82478,"tdoctype":"pCR","for":"Approval","abstract":"This contribution provides a TP to TS 38.141-2 correcting errors in Tx OFF power and transient time measurements for FR1. No changes are done for FR2.","secretary_remarks":"","agenda_item_sort_order":316,"ainumber":"7.9.4.3.3.1","ainame":"FR2 transient time test and OFF powerNR_newRAT-Perf]","tdoc_agenda_sort_order":407300,"status":"revised","reservation_date":"2018-09-28 12:15:44","uploaded":"2018-09-28 17:02:04","revisionof":"","revisedto":"R4-1814074","release":"Rel-15","crspec":"38.141-2","crspecversion":"15.1.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812923.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1813243","title":"NR FR2 Transmitter Off power and Transient time measurement","source":"Keysight Technologies UK Ltd","contact":"Takao Miyake","contact-id":76264,"tdoctype":"discussion","for":"Discussion","abstract":"","secretary_remarks":"","agenda_item_sort_order":316,"ainumber":"7.9.4.3.3.1","ainame":"FR2 transient time test and OFF powerNR_newRAT-Perf]","tdoc_agenda_sort_order":292000,"status":"noted","reservation_date":"2018-09-28 14:30:18","uploaded":"2018-09-28 17:47:21","revisionof":"","revisedto":"","release":"Rel-15","crspec":"","crspecversion":"","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1813243.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1814073","title":"WF on Tx Off power","source":"Nokia, Nokia Shanghai Bell","contact":"Kyoungseok Oh","contact-id":66120,"tdoctype":"other","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":316,"ainumber":"7.9.4.3.3.1","ainame":"FR2 transient time test and OFF powerNR_newRAT-Perf]","tdoc_agenda_sort_order":292300,"status":"approved","reservation_date":"2018-10-18 10:35:03","uploaded":"2018-10-18 10:38:07","revisionof":"","revisedto":"","release":"","crspec":"","crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1814073.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1814074","title":"TP to TS 38.141-2: Corrections on OTA transmit ON\/OFF power","source":"Nokia, Nokia Shanghai Bell","contact":"Kyoungseok Oh","contact-id":66120,"tdoctype":"pCR","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":316,"ainumber":"7.9.4.3.3.1","ainame":"FR2 transient time test and OFF powerNR_newRAT-Perf]","tdoc_agenda_sort_order":407301,"status":"approved","reservation_date":"2018-10-18 10:35:03","uploaded":"2018-10-18 10:38:07","revisionof":"R4-1812923","revisedto":"","release":"Rel-15","crspec":"38.141-2","crspecversion":"1.0.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1814074.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0}]