[{"name":"R4-1812035","title":"P-Max indication and HPUE behaviour","source":"Ericsson","contact":"Christian Bergljung","contact-id":21143,"tdoctype":"other","for":"Approval","abstract":"In this contribution we propose to specify the UE behaviour with P-Max presence\/absence in a band agnostic manner and use P-MPR for HPUE fall-back compliance when the duty-cycle is large","secretary_remarks":"","agenda_item_sort_order":224,"ainumber":"7.6.7.1.1","ainame":"[FR1] UL\/DL duty cycle for HPUE [NR_newRAT-Core]","tdoc_agenda_sort_order":203600,"status":"noted","reservation_date":"2018-09-25 15:04:19","uploaded":"2018-09-26 01:34:06","revisionof":"","revisedto":"","release":"Rel-15","crspec":"","crspecversion":"","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812035.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812036","title":"P-Max indication and applicability of requirements for HPUE (TDD power class 2)","source":"Ericsson","contact":"Christian Bergljung","contact-id":21143,"tdoctype":"draftCR","for":"Endorsement","abstract":"CR to modify behaviour when P-Max is indicated and allow allow P-MPR for HPUE fall-back compliance when the duty-cycle is large.","secretary_remarks":"","agenda_item_sort_order":224,"ainumber":"7.6.7.1.1","ainame":"[FR1] UL\/DL duty cycle for HPUE [NR_newRAT-Core]","tdoc_agenda_sort_order":240900,"status":"noted","reservation_date":"2018-09-25 15:04:19","uploaded":"2018-09-26 01:36:53","revisionof":"","revisedto":"","release":"Rel-15","crspec":"38.101-1","crspecversion":"15.3.0","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812036.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812409","title":"MPR for high power\/high duty cycle transmission","source":"Qualcomm Incorporated","contact":"Gene Fong","contact-id":42643,"tdoctype":"other","for":"Discussion","abstract":"Describes an approach using MPR to allow reduction of the maximum output power to meet SAR when uplink duty cycle is greater than signaled capability","secretary_remarks":"","agenda_item_sort_order":224,"ainumber":"7.6.7.1.1","ainame":"[FR1] UL\/DL duty cycle for HPUE [NR_newRAT-Core]","tdoc_agenda_sort_order":203500,"status":"noted","reservation_date":"2018-09-27 23:22:09","uploaded":"2018-09-28 22:15:37","revisionof":"","revisedto":"","release":"","crspec":"","crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812409.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812715","title":"Further discussion of HPUE behavior","source":"OPPO","contact":"Jinqiang Xing","contact-id":76209,"tdoctype":"discussion","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":224,"ainumber":"7.6.7.1.1","ainame":"[FR1] UL\/DL duty cycle for HPUE [NR_newRAT-Core]","tdoc_agenda_sort_order":271500,"status":"noted","reservation_date":"2018-09-28 10:09:51","uploaded":"2018-09-28 10:47:30","revisionof":"","revisedto":"","release":"Rel-15","crspec":"38.101-1","crspecversion":"","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812715.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812716","title":"Discussion on maxUplinkDutyCycle capability for EN-DC HPUE","source":"OPPO","contact":"Jinqiang Xing","contact-id":76209,"tdoctype":"discussion","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":224,"ainumber":"7.6.7.1.1","ainame":"[FR1] UL\/DL duty cycle for HPUE [NR_newRAT-Core]","tdoc_agenda_sort_order":271600,"status":"noted","reservation_date":"2018-09-28 10:09:51","uploaded":"2018-09-28 10:47:30","revisionof":"","revisedto":"","release":"Rel-15","crspec":"38.101-3","crspecversion":"","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812716.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812717","title":"Introduction of maxUplinkDutyCycle to ENDC HPUE","source":"OPPO","contact":"Jinqiang Xing","contact-id":76209,"tdoctype":"draftCR","for":"Endorsement","abstract":"","secretary_remarks":"","agenda_item_sort_order":224,"ainumber":"7.6.7.1.1","ainame":"[FR1] UL\/DL duty cycle for HPUE [NR_newRAT-Core]","tdoc_agenda_sort_order":271800,"status":"noted","reservation_date":"2018-09-28 10:09:51","uploaded":"2018-09-28 10:47:30","revisionof":"","revisedto":"","release":"Rel-15","crspec":"38.101-3","crspecversion":"15.3.0","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812717.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1812718","title":"Draft LS on UE capability of maxUplinkDutyCycle for FR1 intra-band EN-DC power class 2 UE","source":"OPPO","contact":"Jinqiang Xing","contact-id":76209,"tdoctype":"LS out","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":224,"ainumber":"7.6.7.1.1","ainame":"[FR1] UL\/DL duty cycle for HPUE [NR_newRAT-Core]","tdoc_agenda_sort_order":384000,"status":"noted","reservation_date":"2018-09-28 10:09:51","uploaded":"2018-09-28 10:47:30","revisionof":"","revisedto":"","release":"Rel-15","crspec":"","crspecversion":"","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"RAN2","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1812718.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-1813840","title":"EN-DC duty Cycle for FR1","source":"OPPO","contact":"Kyoungseok Oh","contact-id":66120,"tdoctype":"other","for":"Discussion","abstract":"","secretary_remarks":"","agenda_item_sort_order":224,"ainumber":"7.6.7.1.1","ainame":"[FR1] UL\/DL duty cycle for HPUE [NR_newRAT-Core]","tdoc_agenda_sort_order":271700,"status":"noted","reservation_date":"2018-10-18 08:22:54","uploaded":"2018-10-18 08:27:59","revisionof":"","revisedto":"","release":"","crspec":"","crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_88Bis\/Docs\/R4-1813840.zip","group":"R4","meeting":"R4-88","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0}]