[{"name":"S2-2103812","title":"Clarification on output parameters in OSE","source":"Ericsson","contact":"Shabnam Sultana","contact-id":21207,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarification in the output statistics and prediction such as: S-NSSAI is provided as part of either the application service experience or the slice service experience so it belongs to both. The NSI ID is optional, as well the list of SUPIs and the Ratio.","secretary_remarks":"Confirm Spec version used - CR states 17.0.0! r03 agreed. Revised to S2-2104826.","agenda_item_sort_order":31,"ainumber":"7.5","ainame":"Enablers for Network Automation for 5G (eNA)","tdoc_agenda_sort_order":11620,"status":"revised","reservation_date":"2021-05-06 21:34:43","uploaded":"2021-05-10 21:15:46","revisionof":"","revisedto":"S2-2104826","release":"Rel-16","crspec":23.288,"crspecversion":"16.7.0","workitem":[{"winame":"eNA"}],"crnumber":333.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_145E_Electronic_2021-05\/Docs\/S2-2103812.zip","group":"S2","meeting":"S2-145-e","year":2021,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2103813","title":"Clarification on output parameters in OSE","source":"Ericsson","contact":"Shabnam Sultana","contact-id":21207,"tdoctype":"CR","for":"Approval","abstract":"Rel-17 mirror CR: Summary of change: Clarification in the output statistics and prediction such as: S-NSSAI is provided as part of either the application service experience or the slice service experience so it belongs to both. The list of SUPIs and its related context is also provided by NWDAF in a list of parameters appliable for a list of SUPIs.","secretary_remarks":"r02 agreed. Revised to S2-2104827.","agenda_item_sort_order":31,"ainumber":"7.5","ainame":"Enablers for Network Automation for 5G (eNA)","tdoc_agenda_sort_order":11640,"status":"revised","reservation_date":"2021-05-06 21:34:44","uploaded":"2021-05-10 21:15:46","revisionof":"","revisedto":"S2-2104827","release":"Rel-17","crspec":23.288,"crspecversion":"17.0.0","workitem":[{"winame":"eNA"}],"crnumber":334.0,"crrevision":"","crcategory":"A","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_145E_Electronic_2021-05\/Docs\/S2-2103813.zip","group":"S2","meeting":"S2-145-e","year":2021,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2104248","title":"Clarify the BDT warning procedure with degraded Network performance","source":"Huawei, HiSilicon","contact":"Marco Spini","contact-id":8356,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarify that the PCF is notified the network performance analytics in the area of interest from the NWDAF when the NWDAF determines the network performance goes below the criteria (i.e. the Reporting Threshold) set by the PCF in the Analytics Reporting Information.","secretary_remarks":"r02 agreed. Revised to S2-2104828.","agenda_item_sort_order":31,"ainumber":"7.5","ainame":"Enablers for Network Automation for 5G (eNA)","tdoc_agenda_sort_order":11660,"status":"revised","reservation_date":"2021-05-10 09:44:32","uploaded":"2021-05-10 14:47:21","revisionof":"","revisedto":"S2-2104828","release":"Rel-16","crspec":23.502,"crspecversion":"16.8.0","workitem":[{"winame":"eNA"}],"crnumber":2792.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_145E_Electronic_2021-05\/Docs\/S2-2104248.zip","group":"S2","meeting":"S2-145-e","year":2021,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2104249","title":"Clarify the BDT warning procedure with degraded Network performance","source":"Huawei, HiSilicon","contact":"Marco Spini","contact-id":8356,"tdoctype":"CR","for":"Approval","abstract":"Rel-17 mirror CR: Summary of change: Clarify that the PCF is notified the network performance analytics in the area of interest from the NWDAF when the NWDAF determines the network performance goes below the criteria (i.e. the Reporting Threshold) set by the PCF in the Analytics Reporting Information.","secretary_remarks":"r00 agreed. Revised to S2-2104829.","agenda_item_sort_order":31,"ainumber":"7.5","ainame":"Enablers for Network Automation for 5G (eNA)","tdoc_agenda_sort_order":11680,"status":"revised","reservation_date":"2021-05-10 09:44:33","uploaded":"2021-05-10 14:47:22","revisionof":"","revisedto":"S2-2104829","release":"Rel-17","crspec":23.502,"crspecversion":"17.0.0","workitem":[{"winame":"eNA"}],"crnumber":2793.0,"crrevision":"","crcategory":"A","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_145E_Electronic_2021-05\/Docs\/S2-2104249.zip","group":"S2","meeting":"S2-145-e","year":2021,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2104250","title":"Clarify the BDT warning description with degraded Network performance","source":"Huawei, HiSilicon","contact":"Marco Spini","contact-id":8356,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarify that the PCF is notified the network performance analytics in the area of interest from the NWDAF when the NWDAF determines the network performance goes below the criteria (i.e. the Reporting Threshold) set by the PCF in the Analytics Reporting Information.","secretary_remarks":"Confirm Spec version used - CR states 17.0.0! r03 agreed. Revised to S2-2104830.","agenda_item_sort_order":31,"ainumber":"7.5","ainame":"Enablers for Network Automation for 5G (eNA)","tdoc_agenda_sort_order":11700,"status":"revised","reservation_date":"2021-05-10 09:44:34","uploaded":"2021-05-10 14:47:22","revisionof":"","revisedto":"S2-2104830","release":"Rel-16","crspec":23.503,"crspecversion":"16.8.0","workitem":[{"winame":"eNA"}],"crnumber":588.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_145E_Electronic_2021-05\/Docs\/S2-2104250.zip","group":"S2","meeting":"S2-145-e","year":2021,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2104251","title":"Clarify the BDT warning description with degraded Network performance","source":"Huawei, HiSilicon","contact":"Marco Spini","contact-id":8356,"tdoctype":"CR","for":"Approval","abstract":"Rel-17 mirror CR: Summary of change: Clarify that the PCF is notified the network performance analytics in the area of interest from the NWDAF when the NWDAF determines the network performance goes below the criteria (i.e. the Reporting Threshold) set by the PCF in the Analytics Reporting Information.","secretary_remarks":"Confirm Spec version used - CR states 16.8.0! r00 agreed. Revised to S2-2104831.","agenda_item_sort_order":31,"ainumber":"7.5","ainame":"Enablers for Network Automation for 5G (eNA)","tdoc_agenda_sort_order":11720,"status":"revised","reservation_date":"2021-05-10 09:44:35","uploaded":"2021-05-10 14:47:22","revisionof":"","revisedto":"S2-2104831","release":"Rel-17","crspec":23.503,"crspecversion":"17.0.0","workitem":[{"winame":"eNA"}],"crnumber":589.0,"crrevision":"","crcategory":"A","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_145E_Electronic_2021-05\/Docs\/S2-2104251.zip","group":"S2","meeting":"S2-145-e","year":2021,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2104826","title":"Clarification on output parameters in OSE","source":"Ericsson","contact":"Shabnam Sultana","contact-id":21207,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarification in the output statistics and prediction such as: S-NSSAI is provided as part of either the application service experience or the slice service experience so it belongs to both. The NSI ID is optional, as well the list of S","secretary_remarks":"Revision of S2-2103812r03. Approved","agenda_item_sort_order":31,"ainumber":"7.5","ainame":"Enablers for Network Automation for 5G (eNA)","tdoc_agenda_sort_order":11630,"status":"agreed","reservation_date":"2021-05-25 06:16:55","uploaded":"2021-06-01 06:21:35","revisionof":"S2-2103812","revisedto":"","release":"Rel-16","crspec":23.288,"crspecversion":"16.7.0","workitem":[{"winame":"eNA"}],"crnumber":333.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"SP-210333","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_145E_Electronic_2021-05\/Docs\/S2-2104826.zip","group":"S2","meeting":"S2-145-e","year":2021,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2104827","title":"Clarification on output parameters in OSE","source":"Ericsson","contact":"Shabnam Sultana","contact-id":21207,"tdoctype":"CR","for":"Approval","abstract":"Rel-17 mirror CR: Summary of change: Clarification in the output statistics and prediction such as: S-NSSAI is provided as part of either the application service experience or the slice service experience so it belongs to both. The list of SUPIs and its r","secretary_remarks":"Revision of S2-2103813r02. Approved","agenda_item_sort_order":31,"ainumber":"7.5","ainame":"Enablers for Network Automation for 5G (eNA)","tdoc_agenda_sort_order":11650,"status":"agreed","reservation_date":"2021-05-25 06:16:57","uploaded":"2021-06-01 06:21:35","revisionof":"S2-2103813","revisedto":"","release":"Rel-17","crspec":23.288,"crspecversion":"17.0.0","workitem":[{"winame":"eNA"}],"crnumber":334.0,"crrevision":1.0,"crcategory":"A","tsg_crp":"SP-210333","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_145E_Electronic_2021-05\/Docs\/S2-2104827.zip","group":"S2","meeting":"S2-145-e","year":2021,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2104828","title":"Clarify the BDT warning procedure with degraded Network performance","source":"Huawei, HiSilicon","contact":"Marco Spini","contact-id":8356,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarify that the PCF is notified the network performance analytics in the area of interest from the NWDAF when the NWDAF determines the network performance goes below the criteria (i.e. the Reporting Threshold) set by the PCF in the Ana","secretary_remarks":"Revision of S2-2104248r02. Approved","agenda_item_sort_order":31,"ainumber":"7.5","ainame":"Enablers for Network Automation for 5G (eNA)","tdoc_agenda_sort_order":11670,"status":"agreed","reservation_date":"2021-05-25 06:16:58","uploaded":"2021-06-01 06:21:35","revisionof":"S2-2104248","revisedto":"","release":"Rel-16","crspec":23.502,"crspecversion":"16.8.0","workitem":[{"winame":"eNA"}],"crnumber":2792.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"SP-210333","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_145E_Electronic_2021-05\/Docs\/S2-2104828.zip","group":"S2","meeting":"S2-145-e","year":2021,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2104829","title":"Clarify the BDT warning procedure with degraded Network performance","source":"Huawei, HiSilicon","contact":"Marco Spini","contact-id":8356,"tdoctype":"CR","for":"Approval","abstract":"Rel-17 mirror CR: Summary of change: Clarify that the PCF is notified the network performance analytics in the area of interest from the NWDAF when the NWDAF determines the network performance goes below the criteria (i.e. the Reporting Threshold) set by","secretary_remarks":"Revision of S2-2104249. Approved","agenda_item_sort_order":31,"ainumber":"7.5","ainame":"Enablers for Network Automation for 5G (eNA)","tdoc_agenda_sort_order":11690,"status":"agreed","reservation_date":"2021-05-25 06:16:59","uploaded":"2021-06-01 06:21:35","revisionof":"S2-2104249","revisedto":"","release":"Rel-17","crspec":23.502,"crspecversion":"17.0.0","workitem":[{"winame":"eNA"}],"crnumber":2793.0,"crrevision":1.0,"crcategory":"A","tsg_crp":"SP-210333","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_145E_Electronic_2021-05\/Docs\/S2-2104829.zip","group":"S2","meeting":"S2-145-e","year":2021,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2104830","title":"Clarify the BDT warning description with degraded Network performance","source":"Huawei, HiSilicon","contact":"Marco Spini","contact-id":8356,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarify that the PCF is notified by the NWDAF when the NWDAF determines the network performance in the area of interest goes below the criteria (i.e. the Reporting Threshold) set by the PCF in the Analytics Reporting Information.","secretary_remarks":"Revision of S2-2104250r03. Approved","agenda_item_sort_order":31,"ainumber":"7.5","ainame":"Enablers for Network Automation for 5G (eNA)","tdoc_agenda_sort_order":11710,"status":"agreed","reservation_date":"2021-05-25 06:17:00","uploaded":"2021-06-01 06:21:35","revisionof":"S2-2104250","revisedto":"","release":"Rel-16","crspec":23.503,"crspecversion":"16.8.0","workitem":[{"winame":"eNA"}],"crnumber":588.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"SP-210333","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_145E_Electronic_2021-05\/Docs\/S2-2104830.zip","group":"S2","meeting":"S2-145-e","year":2021,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2104831","title":"Clarify the BDT warning description with degraded Network performance","source":"Huawei, HiSilicon","contact":"Marco Spini","contact-id":8356,"tdoctype":"CR","for":"Approval","abstract":"Rel-17 mirror CR: Summary of change: Clarify that the PCF is notified by the NWDAF when the NWDAF determines the network performance in the area of interest goes below the criteria (i.e. the Reporting Threshold) set by the PCF in the Analytics Reporting I","secretary_remarks":"Revision of S2-2104251. Approved","agenda_item_sort_order":31,"ainumber":"7.5","ainame":"Enablers for Network Automation for 5G (eNA)","tdoc_agenda_sort_order":11730,"status":"agreed","reservation_date":"2021-05-25 06:17:01","uploaded":"2021-06-01 06:21:35","revisionof":"S2-2104251","revisedto":"","release":"Rel-17","crspec":23.503,"crspecversion":"17.0.0","workitem":[{"winame":"eNA"}],"crnumber":589.0,"crrevision":1.0,"crcategory":"A","tsg_crp":"SP-210333","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_145E_Electronic_2021-05\/Docs\/S2-2104831.zip","group":"S2","meeting":"S2-145-e","year":2021,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0}]