[{"name":"R4-2509120","title":"SBFD\/TDD Adjacent Channel UE-UE CLI simulation","source":"Charter Communications, Inc","contact":"Frank Azcuy","contact-id":75429,"tdoctype":"discussion","for":"Approval","abstract":"The purpose of this document is to summarize simulation results for UE-t0-UE CLI interference in the urban hotspot to urban hotspot scenario (scenario 2) and propose several suggestions to add levers that can be used to alleviate or avoid UE-to-UE cross link interference","secretary_remarks":"","agenda_item_sort_order":333,"ainumber":"7.21.2.2","ainame":"Analysis on intra-operator adjacent-channel inter-cell UE-UE CLI and solutions","tdoc_agenda_sort_order":0,"status":"noted","reservation_date":"2025-08-11 16:24:39","uploaded":"2025-08-15 16:06:32","revisionof":"","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ran\/WG4_Radio\/TSGR4_116\/Docs\/R4-2509120.zip","group":"R4","meeting":"R4-116","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2510417","title":"Views on Inter-UE CLI aspects and potential solutions for SBFD deployments","source":"Qualcomm Germany","contact":"Mustafa Emara","contact-id":90636,"tdoctype":"discussion","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":333,"ainumber":"7.21.2.2","ainame":"Analysis on intra-operator adjacent-channel inter-cell UE-UE CLI and solutions","tdoc_agenda_sort_order":0,"status":"noted","reservation_date":"2025-08-15 07:48:31","uploaded":"2025-08-15 16:17:21","revisionof":"","revisedto":"","release":"","crspec":"","crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ran\/WG4_Radio\/TSGR4_116\/Docs\/R4-2510417.zip","group":"R4","meeting":"R4-116","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2511106","title":"On intra-operator adjacent channel inter-cell UE-UE CLI","source":"Huawei, HiSilicon","contact":"Xiang Gao","contact-id":89062,"tdoctype":"other","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":333,"ainumber":"7.21.2.2","ainame":"Analysis on intra-operator adjacent-channel inter-cell UE-UE CLI and solutions","tdoc_agenda_sort_order":0,"status":"noted","reservation_date":"2025-08-15 12:56:40","uploaded":"2025-08-15 13:20:07","revisionof":"","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"NR_duplex_evo-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ran\/WG4_Radio\/TSGR4_116\/Docs\/R4-2511106.zip","group":"R4","meeting":"R4-116","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2511138","title":"Discussion on UE2UE CLI analysis","source":"ZTE Corporation, Sanechips","contact":"Fei Xue","contact-id":59676,"tdoctype":"other","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":333,"ainumber":"7.21.2.2","ainame":"Analysis on intra-operator adjacent-channel inter-cell UE-UE CLI and solutions","tdoc_agenda_sort_order":0,"status":"noted","reservation_date":"2025-08-15 13:32:17","uploaded":"2025-08-15 14:08:45","revisionof":"","revisedto":"","release":"","crspec":"","crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ran\/WG4_Radio\/TSGR4_116\/Docs\/R4-2511138.zip","group":"R4","meeting":"R4-116","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2511251","title":"Analysis on UE-UE CLI problem and potential solutions","source":"Samsung","contact":"He Wang","contact-id":62115,"tdoctype":"other","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":333,"ainumber":"7.21.2.2","ainame":"Analysis on intra-operator adjacent-channel inter-cell UE-UE CLI and solutions","tdoc_agenda_sort_order":0,"status":"noted","reservation_date":"2025-08-15 14:29:31","uploaded":"2025-08-15 18:21:41","revisionof":"","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"NR_duplex_evo-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ran\/WG4_Radio\/TSGR4_116\/Docs\/R4-2511251.zip","group":"R4","meeting":"R4-116","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2511314","title":"Simulation and discussion on SBFD UE-UE CLI","source":"Ericsson","contact":"Zhou Du","contact-id":108130,"tdoctype":"discussion","for":"Discussion","abstract":"In this paper, a detailed analysis for the scenario with intra-operator adjacent-channel inter-cell will be provided using Scenario 2 as reference.","secretary_remarks":"","agenda_item_sort_order":333,"ainumber":"7.21.2.2","ainame":"Analysis on intra-operator adjacent-channel inter-cell UE-UE CLI and solutions","tdoc_agenda_sort_order":0,"status":"noted","reservation_date":"2025-08-15 15:00:41","uploaded":"2025-08-15 19:56:36","revisionof":"","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"NR_duplex_evo-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ran\/WG4_Radio\/TSGR4_116\/Docs\/R4-2511314.zip","group":"R4","meeting":"R4-116","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2511530","title":"On UE-UE CLI problem statement and potential solutions","source":"Nokia","contact":"Veli-Matti Holappa","contact-id":99921,"tdoctype":"other","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":333,"ainumber":"7.21.2.2","ainame":"Analysis on intra-operator adjacent-channel inter-cell UE-UE CLI and solutions","tdoc_agenda_sort_order":0,"status":"noted","reservation_date":"2025-08-15 19:08:34","uploaded":"2025-08-15 19:27:13","revisionof":"","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"NR_duplex_evo-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ran\/WG4_Radio\/TSGR4_116\/Docs\/R4-2511530.zip","group":"R4","meeting":"R4-116","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0}]