[{"name":"C4-225124","title":"PLMN ID related to S-NSSAI","source":"Ericsson","contact":"Yong Yang","contact-id":42295,"tdoctype":"CR","for":"Agreement","abstract":"23.502 4.11.4.3.3 expects that the SMF+PGW-C can provide the ePDG with PLMN ID that the S-NSSAI relates to, and that the ePDG provides the UE with the PLMN ID that the S-NSSAI relates to, so that the UE can associate it with the PDN connection.\n\nThe S-NSSAI is delivered to the UE via a PCO and for ePDG, it is via APCO.\n\nAs specified in TS 24.008 definition of S-NSSAI PCO parameter which states:\n-----------\nWhen the container identifier indicates S-NSSAI, the container identifier contents field contains one S-NSSAI value followed by one PLMN ID that the S-NSSAI relates to. The S-NSSAI value is coded as the value part of S-NSSAI information element as specified in subclause 9.11.2.8 of 3GPP TS 24.501 [167]. The PLMN ID is encoded as the value of the PLMN identity of the CN operator IE in subclause 10.5.5.36. The usage of the S-NSSAI and the associated PLMN ID is defined in 3GPP TS 24.501 [167].\n-----------\n\nIt is proposed to clarify this in GTPv2 spec.","secretary_remarks":"","agenda_item_sort_order":25,"ainumber":"6.3.6","ainame":"GTP [TEI18]","tdoc_agenda_sort_order":51240,"status":"agreed","reservation_date":"2022-11-01 21:49:16","uploaded":"2022-11-04 09:39:53","revisionof":"","revisedto":"","release":"Rel-18","crspec":29.274,"crspecversion":"18.0.0","workitem":[{"winame":"TEI18"}],"crnumber":2063.0,"crrevision":"","crcategory":"F","tsg_crp":"CP-223037","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG4_protocollars_ex-CN4\/TSGCT4_113_Toulouse\/Docs\/C4-225124.zip","group":"C4","meeting":"C4-113","year":2022,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"C4-225149","title":"PC5 QoS Flow IE","source":"Nokia, Nokia Shanghai Bell","contact":"Bruno Landais","contact-id":68755,"tdoctype":"CR","for":"Agreement","abstract":"The definition of the Range flag in the PC5 QoS Flow IE incorrectly refers to octets that are not currently defined in this IE.","secretary_remarks":"","agenda_item_sort_order":25,"ainumber":"6.3.6","ainame":"GTP [TEI18]","tdoc_agenda_sort_order":51490,"status":"agreed","reservation_date":"2022-11-02 09:09:45","uploaded":"2022-11-03 16:20:53","revisionof":"","revisedto":"","release":"Rel-18","crspec":29.274,"crspecversion":"18.0.0","workitem":[{"winame":"TEI18"},{"winame":" eV2XARC"}],"crnumber":2064.0,"crrevision":"","crcategory":"F","tsg_crp":"CP-223037","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG4_protocollars_ex-CN4\/TSGCT4_113_Toulouse\/Docs\/C4-225149.zip","group":"C4","meeting":"C4-113","year":2022,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"C4-225175","title":"USS UAV Authorization\/Authentication during UE requested PDN connectivity procedure","source":"Nokia, Nokia Shanghai Bell","contact":"Mamdoh Shahin","contact-id":96517,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":25,"ainumber":"6.3.6","ainame":"GTP [TEI18]","tdoc_agenda_sort_order":51750,"status":"agreed","reservation_date":"2022-11-02 13:26:51","uploaded":"2022-11-03 12:55:29","revisionof":"","revisedto":"","release":"Rel-18","crspec":29.274,"crspecversion":"18.0.0","workitem":[{"winame":"TEI18"},{"winame":" ID_UAS"}],"crnumber":2065.0,"crrevision":"","crcategory":"F","tsg_crp":"CP-223037","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG4_protocollars_ex-CN4\/TSGCT4_113_Toulouse\/Docs\/C4-225175.zip","group":"C4","meeting":"C4-113","year":2022,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"C4-225298","title":"Per Qos Flow error notification","source":"Intel","contact":"Thomas Luetzenkirchen","contact-id":37722,"tdoctype":"CR","for":"Agreement","abstract":"When sending a G-PDU of a specific Qos Flow of a PDU session there is currently no support for a GTP-U entity to detect if the receiving GTP-U entity is able to process the data of that Qos Flow. For example the receiving GTP-U entity may drop the received G-PDU without sending Error Indication when the PDU session exists but the identified Qos Flow is currently not in use.","secretary_remarks":"","agenda_item_sort_order":25,"ainumber":"6.3.6","ainame":"GTP [TEI18]","tdoc_agenda_sort_order":52980,"status":"postponed","reservation_date":"2022-11-04 09:04:41","uploaded":"2022-11-04 09:14:29","revisionof":"","revisedto":"","release":"Rel-18","crspec":29.281,"crspecversion":"17.4.0","workitem":[{"winame":"TEI18"}],"crnumber":122.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG4_protocollars_ex-CN4\/TSGCT4_113_Toulouse\/Docs\/C4-225298.zip","group":"C4","meeting":"C4-113","year":2022,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0}]