[{"name":"S5-254222","title":"Rel-20 CR TS 28.552 Add UE Address Information Retrieval for UPF event exposure measurement","source":"China Telecom","contact":"Lixin Liang","contact-id":95162,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"Source modified on 9\/30\/2025. Original source : China Telecom","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":42220,"status":"revised","reservation_date":"2025-09-30 14:49:45","uploaded":"2025-09-30 15:11:58","revisionof":"","revisedto":"S5-254716","release":"Rel-20","crspec":"28.552","crspecversion":"20.0.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":732.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254222.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.9.X (new), A.X(new)","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254223","title":"Rel-20 CR TS 28.552 Add UPF event exposure related measurements","source":"China Telecom Corporation Ltd.","contact":"Xiumin Chen","contact-id":70925,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"Title modified on 10\/1\/2025. Original title : Rel-20 CR TS 28.552 Add UPF event  exposure related measurements<br\/><br\/>Source modified on 10\/1\/2025. Original source : China Telecom Corporation Ltd.","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":42230,"status":"revised","reservation_date":"2025-09-30 14:56:11","uploaded":"2025-10-01 10:00:48","revisionof":"","revisedto":"S5-254717","release":"Rel-20","crspec":"28.552","crspecversion":"20.0.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":733.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254223.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.4.X(new), A.X(new)","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254224","title":"Rel-20 CR TS 28.552 Add measurements of UPF related information exposed","source":"China Telecom Corporation Ltd.","contact":"Xiumin Chen","contact-id":70925,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":42240,"status":"agreed","reservation_date":"2025-09-30 15:10:58","uploaded":"2025-10-01 10:00:48","revisionof":"","revisedto":"","release":"Rel-20","crspec":"28.552","crspecversion":"20.0.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":734.0,"crrevision":"","crcategory":"B","tsg_crp":"SP-251382","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254224.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254225","title":"Rel-20 CR 28.554 Add new KPI equivalent RRC connection number for transient overload scenarios","source":"China Unicom","contact":"Zhen Xing","contact-id":99712,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"Source modified on 9\/30\/2025. Original source : China Unicom","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":42250,"status":"not pursued","reservation_date":"2025-09-30 15:18:14","uploaded":"2025-09-30 15:34:32","revisionof":"","revisedto":"","release":"Rel-20","crspec":"28.554","crspecversion":"19.5.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":248.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254225.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":true,"cn_affected":false,"clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254226","title":"Rel-20 CR 28.554 Add operator-specific energy consumption and energy efficiency KPIs for network sharing scenario","source":"China Unicom","contact":"Zhen Xing","contact-id":99712,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"Source modified on 9\/30\/2025. Original source : China Unicom","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":42260,"status":"not pursued","reservation_date":"2025-09-30 15:21:29","uploaded":"2025-09-30 15:34:32","revisionof":"","revisedto":"","release":"Rel-20","crspec":"28.554","crspecversion":"19.5.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":249.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254226.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":true,"cn_affected":false,"clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254227","title":"Rel-20 CR 28.554 Add energy efficiency KPI of HDLLC network slice for XR","source":"China Unicom","contact":"Zhen Xing","contact-id":99712,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"Source modified on 9\/30\/2025. Original source : China Unicom","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":42270,"status":"not pursued","reservation_date":"2025-09-30 15:24:21","uploaded":"2025-09-30 15:34:32","revisionof":"","revisedto":"","release":"Rel-20","crspec":"28.554","crspecversion":"19.5.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":250.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254227.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":true,"cn_affected":false,"clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254252","title":"Rel-20 CR TS 28.554 Corrections on KPI naming","source":"Ericsson","contact":"Qiang Zu","contact-id":42296,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"Source modified on 10\/3\/2025. Original source : Ericsson Japan K.K.","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":42520,"status":"not pursued","reservation_date":"2025-09-30 20:16:17","uploaded":"2025-10-03 16:03:08","revisionof":"","revisedto":"","release":"Rel-20","crspec":"28.554","crspecversion":"19.5.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":252.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254252.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":true,"cn_affected":true,"clauses_affected":" 2,4,5, 6.2, 6.3, 6.4, 6.5, 6.6, 6.7, 6.8, 6.11","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254253","title":"Rel-20 CR TS 32.423 Additional Trace References","source":"Ericsson Japan K.K.","contact":"Qiang Zu","contact-id":42296,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":42530,"status":"withdrawn","reservation_date":"2025-09-30 20:18:36","uploaded":null,"revisionof":"","revisedto":"S5-255059","release":"Rel-20","crspec":"32.423","crspecversion":"19.4.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":215.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254254","title":"Rel-20 CR TS 32.423 Trace Record Schema Optimization","source":"Ericsson Japan K.K.","contact":"Qiang Zu","contact-id":42296,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":42540,"status":"withdrawn","reservation_date":"2025-09-30 20:22:04","uploaded":null,"revisionof":"","revisedto":"S5-255060","release":"Rel-20","crspec":"32.423","crspecversion":"19.4.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":216.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254255","title":"Rel-20 CR TS 32.423 Trace message direction","source":"Ericsson, AT&T","contact":"Qiang Zu","contact-id":42296,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":42550,"status":"withdrawn","reservation_date":"2025-09-30 20:24:00","uploaded":null,"revisionof":"","revisedto":"S5-255061","release":"Rel-20","crspec":"32.423","crspecversion":"19.4.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":217.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254344","title":"Rel-20 CR TS 32.423 VS Trace Record Payload","source":"Ericsson Japan K.K.","contact":"Qiang Zu","contact-id":42296,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":43440,"status":"withdrawn","reservation_date":"2025-10-01 18:39:41","uploaded":null,"revisionof":"","revisedto":"S5-255062","release":"Rel-20","crspec":"32.423","crspecversion":"19.4.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":218.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254373","title":"Rel-20 CR TS 28.552 Add DL data transmission time per SSB","source":"China Unicom","contact":"Zhaoning Wang","contact-id":91259,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":43730,"status":"revised","reservation_date":"2025-10-02 09:22:59","uploaded":"2025-10-03 15:53:19","revisionof":"","revisedto":"S5-254720","release":"Rel-20","crspec":"28.552","crspecversion":"20.0.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":737.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254373.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254374","title":"Rel-20 CR TS 28.552 Add Timing Advance distribution for NR Cell per SSB","source":"China Unicom","contact":"Zhaoning Wang","contact-id":91259,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":0,"status":"revised","reservation_date":"2025-10-02 09:24:14","uploaded":"2025-10-03 15:54:27","revisionof":"","revisedto":"S5-254721","release":"Rel-20","crspec":"28.552","crspecversion":"20.0.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":738.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254374.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254599","title":"DP for Fixing corrupted TS 28.554 spec","source":"ZTE Corporation","contact":"Bangqiu Ruan","contact-id":96106,"tdoctype":"discussion","for":"Endorsement","abstract":"Endorse the following to ensure the new CRs can be properly implemented: \n MCC creates a fresh, clean .docx (no Compatibility Mode): \n(1)\tNo \u201cCompatibility Mode\u201d in File > Info\n(2)\t\u201cInsert\/paste equations as OMML\u201d enabled\n(3)\t New CR equations remain editable (OMML) \n\n Note: Existing picture equations remain unchanged initially.  Given the workload, the correction can be contribution-driven.","secretary_remarks":"","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":45990,"status":"noted","reservation_date":"2025-10-03 17:21:32","uploaded":"2025-10-03 22:03:13","revisionof":"","revisedto":"","release":"Rel-20","crspec":"28.554","crspecversion":"","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254599.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254716","title":"Rel-20 CR TS 28.552 Add UE Address Information Retrieval for UPF event exposure measurement","source":"China Telecom","contact":"Ingbert Sigovich","contact-id":28887,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"Source modified on 21\/10\/2025. Original source : China Telecom","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":42221,"status":"agreed","reservation_date":"2025-10-21 05:47:51","uploaded":"2025-10-21 05:51:07","revisionof":"S5-254222","revisedto":"","release":"Rel-20","crspec":"28.552","crspecversion":"20.0.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":732.0,"crrevision":1.0,"crcategory":"B","tsg_crp":"SP-251382","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254716.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.9.X (new), A.X(new)","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254717","title":"Rel-20 CR TS 28.552 Add UPF event exposure related measurements","source":"China Telecom Corporation Ltd.","contact":"Ingbert Sigovich","contact-id":28887,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":42231,"status":"agreed","reservation_date":"2025-10-21 05:47:51","uploaded":"2025-10-21 05:51:07","revisionof":"S5-254223","revisedto":"","release":"Rel-20","crspec":"28.552","crspecversion":"20.0.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":733.0,"crrevision":1.0,"crcategory":"B","tsg_crp":"SP-251382","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254717.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254720","title":"Rel-20 CR TS 28.552 Add DL data transmission time per SSB","source":"China Unicom","contact":"Ingbert Sigovich","contact-id":28887,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":43731,"status":"agreed","reservation_date":"2025-10-21 05:47:52","uploaded":"2025-10-21 05:51:07","revisionof":"S5-254373","revisedto":"","release":"Rel-20","crspec":"28.552","crspecversion":"20.0.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":737.0,"crrevision":1.0,"crcategory":"B","tsg_crp":"SP-251382","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254720.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S5-254721","title":"Rel-20 CR TS 28.552 Add Timing Advance distribution for NR Cell per SSB","source":"China Unicom","contact":"Ingbert Sigovich","contact-id":28887,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":85,"ainumber":"6.20.12","ainame":"5G performance measurements\/KPIs and Trace\/MDT\/QoE","tdoc_agenda_sort_order":43741,"status":"agreed","reservation_date":"2025-10-21 05:47:53","uploaded":"2025-10-21 05:51:07","revisionof":"S5-254374","revisedto":"","release":"Rel-20","crspec":"28.552","crspecversion":"20.0.0","workitem":[{"winame":"PM_KPI_Trace_MDT_QoE-OAM"}],"crnumber":738.0,"crrevision":1.0,"crcategory":"B","tsg_crp":"SP-251382","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG5_TM\/TSGS5_163\/Docs\/S5-254721.zip","group":"S5","meeting":"S5-163","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0}]