[{"name":"R5-252019","title":"Update for TDD RMCs for sustained data rate testing","source":"ROHDE & SCHWARZ","contact":"Niels Petrovic","contact-id":49274,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":665,"ainumber":"5.4.7.4","ainame":"Clauses 1-4, Annexes","tdoc_agenda_sort_order":20190,"status":"agreed","reservation_date":"2025-05-05 09:26:18","uploaded":"2025-05-08 12:52:20","revisionof":"","revisedto":"","release":"Rel-18","crspec":"38.521-4","crspecversion":"18.6.1","workitem":[{"winame":"TEI15_Test"},{"winame":" 5GS_NR_LTE-UEConTest"}],"crnumber":963.0,"crrevision":"","crcategory":"F","tsg_crp":"RP-251117","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ran\/WG5_Test_ex-T1\/TSGR5__107_Malta\/Docs\/R5-252019.zip","group":"R5","meeting":"R5-107","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"R5-252246","title":"Correction of Reference for Isolation Procedure","source":"Keysight Technologies UK Ltd","contact":"Thorsten Hertel","contact-id":77978,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"Source modified on 5\/9\/2025. Original source : Keysight Technologies UK Ltd","agenda_item_sort_order":665,"ainumber":"5.4.7.4","ainame":"Clauses 1-4, Annexes","tdoc_agenda_sort_order":22460,"status":"agreed","reservation_date":"2025-07-05 21:30:51","uploaded":"2025-05-09 16:38:29","revisionof":"","revisedto":"","release":"Rel-18","crspec":"38.521-4","crspecversion":"18.6.1","workitem":[{"winame":"TEI15_Test"},{"winame":" 5GS_NR_LTE-UEConTest"}],"crnumber":966.0,"crrevision":"","crcategory":"F","tsg_crp":"RP-251117","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ran\/WG5_Test_ex-T1\/TSGR5__107_Malta\/Docs\/R5-252246.zip","group":"R5","meeting":"R5-107","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":false,"clauses_affected":"2, H.2","crsinpack":null,"crsinpacknumber":0},
{"name":"R5-252557","title":"Update of MU for frequencies up to 7.125 GHz","source":"Ericsson","contact":"Petter Karlsson","contact-id":76182,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"Source modified on 5\/9\/2025. Original source : Ericsson<br\/><br\/>Source modified on 09\/05\/2025. Original source : Ericsson","agenda_item_sort_order":665,"ainumber":"5.4.7.4","ainame":"Clauses 1-4, Annexes","tdoc_agenda_sort_order":25570,"status":"revised","reservation_date":"2025-09-05 07:53:25","uploaded":"2025-05-09 11:51:27","revisionof":"","revisedto":"R5-253602","release":"Rel-18","crspec":"38.521-4","crspecversion":"18.6.1","workitem":[{"winame":"TEI16_Test"},{"winame":" NR_unlic-UEConTest"}],"crnumber":975.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ran\/WG5_Test_ex-T1\/TSGR5__107_Malta\/Docs\/R5-252557.zip","group":"R5","meeting":"R5-107","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":false,"clauses_affected":"F.1.1.2","crsinpack":null,"crsinpacknumber":0},
{"name":"R5-252878","title":"Alignment for SINR definition with TS 38.101-4","source":"Keysight Technologies","contact":"Fran Martos","contact-id":110697,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"Source modified on 5\/9\/2025. Original source : Keysight Technologies UK Ltd","agenda_item_sort_order":665,"ainumber":"5.4.7.4","ainame":"Clauses 1-4, Annexes","tdoc_agenda_sort_order":28780,"status":"agreed","reservation_date":"2025-09-05 16:58:51","uploaded":"2025-05-09 17:02:25","revisionof":"","revisedto":"","release":"Rel-18","crspec":"38.521-4","crspecversion":"18.6.1","workitem":[{"winame":"TEI17_Test"},{"winame":" NR_demod_enh2-UEConTest"}],"crnumber":977.0,"crrevision":"","crcategory":"F","tsg_crp":"RP-251119","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ran\/WG5_Test_ex-T1\/TSGR5__107_Malta\/Docs\/R5-252878.zip","group":"R5","meeting":"R5-107","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":false,"clauses_affected":"4.4","crsinpack":null,"crsinpacknumber":0},
{"name":"R5-253602","title":"Update of MU for frequencies up to 7.125 GHz","source":"Ericsson","contact":"Ingbert Sigovich","contact-id":28887,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":665,"ainumber":"5.4.7.4","ainame":"Clauses 1-4, Annexes","tdoc_agenda_sort_order":25571,"status":"agreed","reservation_date":"2025-05-28 16:12:59","uploaded":"2025-05-28 16:21:09","revisionof":"R5-252557","revisedto":"","release":"Rel-18","crspec":"38.521-4","crspecversion":"18.6.1","workitem":[{"winame":"TEI16_Test"},{"winame":" NR_unlic-UEConTest"}],"crnumber":975.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"RP-251139","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ran\/WG5_Test_ex-T1\/TSGR5__107_Malta\/Docs\/R5-253602.zip","group":"R5","meeting":"R5-107","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":false,"clauses_affected":"F.1.1.2","crsinpack":null,"crsinpacknumber":0}]