[{"name":"R5-202119","title":"CR to 38.521-2 to correct Clenshaw-Curtis Weights at the Poles for CDF\/CCDF","source":"Keysight Technologies UK Ltd, Verizon, ETS-Lindgren Europe","contact":"Thorsten Hertel","contact-id":77978,"tdoctype":"CR","for":"Agreement","abstract":"This contribution provides the necessary guidance how to apply the Clenshaw Curtis weights when just a single EIRP\/EIS measurement is performed at the poles.","secretary_remarks":"","agenda_item_sort_order":61,"ainumber":"5.3.2.5","ainame":"\tTS 38.521-2","tdoc_agenda_sort_order":21190,"status":"revised","reservation_date":"2020-05-08 00:06:22","uploaded":"2020-05-08 23:08:17","revisionof":"","revisedto":"R5-202720","release":"Rel-16","crspec":"38.521-2","crspecversion":"16.3.0","workitem":[{"winame":"5GS_NR_LTE-UEConTest"}],"crnumber":345.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG5_Test_ex-T1\/TSGR5_87_Electronic\/Docs\/R5-202119.zip","group":"R5","meeting":"R5-ah-38102","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R5-202120","title":"CR to 38.521-2 to correct Clenshaw-Curtis Weight Equations","source":"Keysight Technologies UK Ltd, Verizon, ETS-Lindgren Europe","contact":"Thorsten Hertel","contact-id":77978,"tdoctype":"CR","for":"Agreement","abstract":"This contribution revises the Clenshaw-Curtis weights, specifically the bj and ci definitions.","secretary_remarks":"","agenda_item_sort_order":61,"ainumber":"5.3.2.5","ainame":"\tTS 38.521-2","tdoc_agenda_sort_order":21200,"status":"agreed","reservation_date":"2020-05-08 00:06:23","uploaded":"2020-05-08 23:08:17","revisionof":"","revisedto":"","release":"Rel-16","crspec":"38.521-2","crspecversion":"16.3.0","workitem":[{"winame":"5GS_NR_LTE-UEConTest"}],"crnumber":346.0,"crrevision":"","crcategory":"F","tsg_crp":"RP-200578","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG5_Test_ex-T1\/TSGR5_87_Electronic\/Docs\/R5-202120.zip","group":"R5","meeting":"R5-ah-38102","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R5-202121","title":"CR to 38.521-2 to properly define Link and Meas Angles","source":"Keysight Technologies UK Ltd","contact":"Thorsten Hertel","contact-id":77978,"tdoctype":"CR","for":"Agreement","abstract":"This CR is correcting Link and Meas definitions for FR2 test cases. A similar CR is introduced in RAN4 (R4-2002734)","secretary_remarks":"","agenda_item_sort_order":61,"ainumber":"5.3.2.5","ainame":"\tTS 38.521-2","tdoc_agenda_sort_order":21210,"status":"revised","reservation_date":"2020-05-08 00:06:24","uploaded":"2020-05-08 23:08:17","revisionof":"","revisedto":"R5-202721","release":"Rel-16","crspec":"38.521-2","crspecversion":"16.3.0","workitem":[{"winame":"5GS_NR_LTE-UEConTest"}],"crnumber":347.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG5_Test_ex-T1\/TSGR5_87_Electronic\/Docs\/R5-202121.zip","group":"R5","meeting":"R5-ah-38102","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R5-202122","title":"CR to 38.521-2 to clarify the applicability of QoQZ validation","source":"Keysight Technologies UK Ltd","contact":"Thorsten Hertel","contact-id":77978,"tdoctype":"CR","for":"Agreement","abstract":"This contribution clarifies that the QoQZ procedure in Annex O is applicable to PC3 and PC1 devices.","secretary_remarks":"","agenda_item_sort_order":61,"ainumber":"5.3.2.5","ainame":"\tTS 38.521-2","tdoc_agenda_sort_order":21220,"status":"agreed","reservation_date":"2020-05-08 00:06:25","uploaded":"2020-05-08 23:08:17","revisionof":"","revisedto":"","release":"Rel-16","crspec":"38.521-2","crspecversion":"16.3.0","workitem":[{"winame":"5GS_NR_LTE-UEConTest"}],"crnumber":348.0,"crrevision":"","crcategory":"F","tsg_crp":"RP-200578","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG5_Test_ex-T1\/TSGR5_87_Electronic\/Docs\/R5-202122.zip","group":"R5","meeting":"R5-ah-38102","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R5-202381","title":"CR to 38.521-2: On the order of test steps for output power dynamics test cases","source":"Keysight Technologies UK Ltd","contact":"Thorsten Hertel","contact-id":77978,"tdoctype":"CR","for":"Agreement","abstract":"This CR adjusts the order of test steps of output power dynamics test cases and remaining transmitter test cases to harmonize on the test step order","secretary_remarks":"","agenda_item_sort_order":61,"ainumber":"5.3.2.5","ainame":"\tTS 38.521-2","tdoc_agenda_sort_order":23810,"status":"revised","reservation_date":"2020-05-08 15:25:53","uploaded":"2020-05-08 23:08:17","revisionof":"","revisedto":"R5-202943","release":"Rel-16","crspec":"38.521-2","crspecversion":"16.3.0","workitem":[{"winame":"5GS_NR_LTE-UEConTest"}],"crnumber":363.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG5_Test_ex-T1\/TSGR5_87_Electronic\/Docs\/R5-202381.zip","group":"R5","meeting":"R5-ah-38102","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R5-202720","title":"CR to 38.521-2 to correct Clenshaw-Curtis Weights at the Poles for CDF\/CCDF","source":"Keysight Technologies UK Ltd, Verizon, ETS-Lindgren Europe","contact":"Ingbert Sigovich","contact-id":28887,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":61,"ainumber":"5.3.2.5","ainame":"\tTS 38.521-2","tdoc_agenda_sort_order":21191,"status":"agreed","reservation_date":"2020-06-01 16:33:58","uploaded":"2020-06-10 14:56:20","revisionof":"R5-202119","revisedto":"","release":"Rel-16","crspec":"38.521-2","crspecversion":"16.3.0","workitem":[{"winame":"5GS_NR_LTE-UEConTest"}],"crnumber":345.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"RP-200578","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG5_Test_ex-T1\/TSGR5_87_Electronic\/Docs\/R5-202720.zip","group":"R5","meeting":"R5-ah-38102","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R5-202721","title":"CR to 38.521-2 to properly define Link and Meas Angles","source":"Keysight Technologies UK Ltd","contact":"Ingbert Sigovich","contact-id":28887,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":61,"ainumber":"5.3.2.5","ainame":"\tTS 38.521-2","tdoc_agenda_sort_order":21211,"status":"revised","reservation_date":"2020-06-01 16:33:59","uploaded":"2020-06-10 14:56:20","revisionof":"R5-202121","revisedto":"R5-203117","release":"Rel-16","crspec":"38.521-2","crspecversion":"16.3.0","workitem":[{"winame":"5GS_NR_LTE-UEConTest"}],"crnumber":347.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG5_Test_ex-T1\/TSGR5_87_Electronic\/Docs\/R5-202721.zip","group":"R5","meeting":"R5-ah-38102","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R5-202943","title":"CR to 38.521-2: On the order of test steps for output power dynamics test cases","source":"Keysight Technologies UK Ltd","contact":"Ingbert Sigovich","contact-id":28887,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":61,"ainumber":"5.3.2.5","ainame":"\tTS 38.521-2","tdoc_agenda_sort_order":23811,"status":"agreed","reservation_date":"2020-06-01 17:00:02","uploaded":"2020-06-10 14:56:28","revisionof":"R5-202381","revisedto":"","release":"Rel-16","crspec":"38.521-2","crspecversion":"16.3.0","workitem":[{"winame":"5GS_NR_LTE-UEConTest"}],"crnumber":363.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"RP-200578","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG5_Test_ex-T1\/TSGR5_87_Electronic\/Docs\/R5-202943.zip","group":"R5","meeting":"R5-ah-38102","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R5-203117","title":"CR to 38.521-2 to properly define Link and Meas Angles","source":"Keysight Technologies UK Ltd","contact":"Ingbert Sigovich","contact-id":28887,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":61,"ainumber":"5.3.2.5","ainame":"\tTS 38.521-2","tdoc_agenda_sort_order":21212,"status":"agreed","reservation_date":"2020-06-10 08:23:06","uploaded":"2020-06-10 14:56:29","revisionof":"R5-202721","revisedto":"","release":"Rel-16","crspec":"38.521-2","crspecversion":"16.3.0","workitem":[{"winame":"5GS_NR_LTE-UEConTest"}],"crnumber":347.0,"crrevision":2.0,"crcategory":"F","tsg_crp":"RP-200578","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG5_Test_ex-T1\/TSGR5_87_Electronic\/Docs\/R5-203117.zip","group":"R5","meeting":"R5-ah-38102","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0}]