[{"name":"R4-2007058","title":"Proposal for EMC reduction of test configurations","source":"Ericsson","contact":"Luis Martinez","contact-id":72675,"tdoctype":"discussion","for":"Approval","abstract":"Proposal for EMC reduction of test configurations","secretary_remarks":"","agenda_item_sort_order":47,"ainumber":"4.8.3","ainame":"Performance requirements [NR_newRAT-Perf]","tdoc_agenda_sort_order":4880,"status":"noted","reservation_date":"2020-05-15 09:14:32","uploaded":"2020-05-15 14:42:29","revisionof":"","revisedto":"","release":"Rel-16","crspec":"","crspecversion":"","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_95_e\/Docs\/R4-2007058.zip","group":"R4","meeting":"R4-ah-38108","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2007059","title":"Draft CR to 37.113 Introducing Reverberation Chamber","source":"Ericsson, ZTE","contact":"Luis Martinez","contact-id":72675,"tdoctype":"CR","for":"Agreement","abstract":"In this CR, reverberation chamber use is included to TS 37.113. Resubmission of endorsed Draft CR R4-2005565","secretary_remarks":"","agenda_item_sort_order":47,"ainumber":"4.8.3","ainame":"Performance requirements [NR_newRAT-Perf]","tdoc_agenda_sort_order":4890,"status":"revised","reservation_date":"2020-05-15 09:14:32","uploaded":"2020-05-15 14:42:29","revisionof":"","revisedto":"R4-2008726","release":"Rel-15","crspec":"37.113","crspecversion":"15.8.0","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":109.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_95_e\/Docs\/R4-2007059.zip","group":"R4","meeting":"R4-ah-38108","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2007547","title":"[R15]CR to TS 37.114 Add the reverberation chamber for radiated immunity testing (clause 2","source":"ZTE Corporation","contact":"Rui Zhou","contact-id":73796,"tdoctype":"CR","for":"Agreement","abstract":"This is the re-submission of endorsed draftCR in RAN4#94-bis-e:\nR4-2005563.\nThere is no reverberation chamber test site for radiated immunity testing.","secretary_remarks":"","agenda_item_sort_order":47,"ainumber":"4.8.3","ainame":"Performance requirements [NR_newRAT-Perf]","tdoc_agenda_sort_order":4910,"status":"revised","reservation_date":"2020-05-15 14:32:41","uploaded":"2020-05-15 15:01:42","revisionof":"","revisedto":"R4-2008728","release":"Rel-15","crspec":"37.114","crspecversion":"15.8.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":97.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_95_e\/Docs\/R4-2007547.zip","group":"R4","meeting":"R4-ah-38108","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2007549","title":"[R15]CR to TS 38.113 Add the reverberation chamber for radiated immunity testing (clause 2","source":"ZTE Corporation","contact":"Rui Zhou","contact-id":73796,"tdoctype":"CR","for":"Agreement","abstract":"This is the re-submission of endorsed draftCR in RAN4#94-bis-e:\nR4-2005564.\nThere is no reverberation chamber test site for radiated immunity testing.","secretary_remarks":"","agenda_item_sort_order":47,"ainumber":"4.8.3","ainame":"Performance requirements [NR_newRAT-Perf]","tdoc_agenda_sort_order":4940,"status":"revised","reservation_date":"2020-05-15 14:32:43","uploaded":"2020-05-15 15:01:42","revisionof":"","revisedto":"R4-2008729","release":"Rel-15","crspec":"38.113","crspecversion":"15.9.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":20.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_95_e\/Docs\/R4-2007549.zip","group":"R4","meeting":"R4-ah-38108","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2008726","title":"Draft CR to 37.113 Introducing Reverberation Chamber","source":"Ericsson, ZTE","contact":"Kai-Erik Sunell","contact-id":74524,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":47,"ainumber":"4.8.3","ainame":"Performance requirements [NR_newRAT-Perf]","tdoc_agenda_sort_order":4900,"status":"agreed","reservation_date":"2020-06-07 16:35:21","uploaded":"2020-06-10 14:56:39","revisionof":"R4-2007059","revisedto":"","release":"Rel-15","crspec":"37.113","crspecversion":"15.8.0","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":109.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"RP-200984","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_95_e\/Docs\/R4-2008726.zip","group":"R4","meeting":"R4-ah-38108","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2008728","title":"[R15]CR to TS 37.114 Add the reverberation chamber for radiated immunity testing (clause 2","source":"ZTE Corporation","contact":"Kai-Erik Sunell","contact-id":74524,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":47,"ainumber":"4.8.3","ainame":"Performance requirements [NR_newRAT-Perf]","tdoc_agenda_sort_order":4930,"status":"agreed","reservation_date":"2020-06-07 16:35:23","uploaded":"2020-06-10 14:56:39","revisionof":"R4-2007547","revisedto":"","release":"Rel-15","crspec":"37.114","crspecversion":"15.8.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":97.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"RP-200984","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_95_e\/Docs\/R4-2008728.zip","group":"R4","meeting":"R4-ah-38108","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2008729","title":"[R15]CR to TS 38.113 Add the reverberation chamber for radiated immunity testing (clause 2","source":"ZTE Corporation","contact":"Kai-Erik Sunell","contact-id":74524,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":47,"ainumber":"4.8.3","ainame":"Performance requirements [NR_newRAT-Perf]","tdoc_agenda_sort_order":4960,"status":"agreed","reservation_date":"2020-06-07 16:35:25","uploaded":"2020-06-10 14:56:39","revisionof":"R4-2007549","revisedto":"","release":"Rel-15","crspec":"38.113","crspecversion":"15.9.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":20.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"RP-200986","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_95_e\/Docs\/R4-2008729.zip","group":"R4","meeting":"R4-ah-38108","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0}]