[{"name":"R4-2009573","title":"Update to FR2 Annex B RRM side conditions","source":"ANRITSU LTD","contact":"Ian Rose","contact-id":9381,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":46,"ainumber":"4.8.1","ainame":"General [NR_newRAT-Perf]","tdoc_agenda_sort_order":3470,"status":"agreed","reservation_date":"2020-08-04 16:17:50","uploaded":"2020-08-04 16:51:53","revisionof":"","revisedto":"","release":"Rel-15","crspec":"38.133","crspecversion":"15.10.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":910.0,"crrevision":"","crcategory":"F","tsg_crp":"RP-201512","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_96_e\/Docs\/R4-2009573.zip","group":"R4","meeting":"R4-96-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2009574","title":"Update to FR2 Annex B RRM side conditions","source":"ANRITSU LTD","contact":"Ian Rose","contact-id":9381,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":46,"ainumber":"4.8.1","ainame":"General [NR_newRAT-Perf]","tdoc_agenda_sort_order":3480,"status":"agreed","reservation_date":"2020-08-04 16:22:04","uploaded":"2020-08-30 10:14:28","revisionof":"","revisedto":"","release":"Rel-16","crspec":"38.133","crspecversion":"16.4.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":911.0,"crrevision":"","crcategory":"A","tsg_crp":"RP-201512","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_96_e\/Docs\/R4-2009574.zip","group":"R4","meeting":"R4-96-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2010857","title":"CR to TS 38.133: Corrections to CSI-RS configurations in A.3.14 (Rel-15)","source":"Rohde & Schwarz","contact":"Bledar Karajani","contact-id":41759,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":46,"ainumber":"4.8.1","ainame":"General [NR_newRAT-Perf]","tdoc_agenda_sort_order":3390,"status":"agreed","reservation_date":"2020-08-07 12:36:57","uploaded":"2020-08-07 21:33:46","revisionof":"","revisedto":"","release":"Rel-15","crspec":"38.133","crspecversion":"15.10.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":1024.0,"crrevision":"","crcategory":"F","tsg_crp":"RP-201512","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_96_e\/Docs\/R4-2010857.zip","group":"R4","meeting":"R4-96-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2010858","title":"CR to TS 38.133: Corrections to CSI-RS configurations in A.3.14 (Rel-16)","source":"Rohde & Schwarz","contact":"Bledar Karajani","contact-id":41759,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":46,"ainumber":"4.8.1","ainame":"General [NR_newRAT-Perf]","tdoc_agenda_sort_order":3400,"status":"agreed","reservation_date":"2020-08-07 12:36:57","uploaded":"2020-08-30 10:15:59","revisionof":"","revisedto":"","release":"Rel-16","crspec":"38.133","crspecversion":"16.4.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":1025.0,"crrevision":"","crcategory":"A","tsg_crp":"RP-201512","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_96_e\/Docs\/R4-2010858.zip","group":"R4","meeting":"R4-96-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2011099","title":"Addition of new default configurations for RMC scheduling","source":"Huawei, Hisilicon","contact":"Jing Han","contact-id":47284,"tdoctype":"CR","for":"Agreement","abstract":"In current default configuration for RMC shceduling (CCR.1.1 TDD\/FDD), 24 RBs are allocated for CORESET and Aggregation level is set to 8. These setting are incompatible with test frequencies setting given in 38.508-1 under some cases.\nTake band n3 for example. Test frequency for band n3 mid range is given in 38.508-1 Table 4.3.1.1.1.3-1 as follows\nSo SSB for mid range of band n3 is 102 RB+2 subcarrier away from point A. If we want to verify TC A.6.6.1.3 on this band, then the start position of active DL BWP (DLBWP.1.2 is used in 6.6.1.3) shall be 103 RB away from point A according to table A.3.9.2.2-1 note 1:\nBWP Parameters\nUnit\nValues\nReference BWP\nDLBWP.1.2\nStarting PRB index\nRBb Note 1\nBandwidth\nRB\n25 for SCS = 15KHz,\n51 for SCS = 30KHz,\n32 for SCS = 120KHz\nNote 1:RBb is the lowest PRB index to guarantee the BWP not fully overlapped with SSB PRB index (RBJ, RBJ+1,.\u2026, RBJ+19) which is defined in Clause A.3.10.\nNote 2:RBa is the lowest PRB index to guarantee the BWP including SSB PRB index (RBJ, RBJ+1,.\u2026, RBJ+19) which is defined in Clause A.3.10.\nHowever, according to RAN1 specs, start position and allocated RB size of CORESET for scheduling RMC shall both be multiple of 6 RBs. As a result, start position of CORESET for scheduling RMC can only be 108 RBs away from point A. Then the 24RB CORESET can not be completely contained in active DL BWP, active DL BWP can only contain a 18 RB CORESET, But 18 RB is not enough for a PDCCH with  aggregation level = 8 because 6 (CCE size)\/2(duration of CORESET)*8(Aggregation level) = 24RB are needed.\nTo solve this issue and avoid impact to RAN5\u2019s other test works. there seems to be no other way but introduce a new configuration of 18RB size and Aggregation level = 4 for RMC scheduling, and use this new configuration in TC A.4.6.1.3\/4\/6 and A.6.1.1.3\/4\/6.","secretary_remarks":"","agenda_item_sort_order":46,"ainumber":"4.8.1","ainame":"General [NR_newRAT-Perf]","tdoc_agenda_sort_order":3410,"status":"revised","reservation_date":"2020-08-07 14:25:48","uploaded":"2020-08-07 15:36:31","revisionof":"","revisedto":"R4-2012067","release":"Rel-15","crspec":"38.133","crspecversion":"15.10.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":1051.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_96_e\/Docs\/R4-2011099.zip","group":"R4","meeting":"R4-96-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2011100","title":"Addition of new default configurations for RMC scheduling_r16","source":"Huawei, Hisilicon","contact":"Jing Han","contact-id":47284,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":46,"ainumber":"4.8.1","ainame":"General [NR_newRAT-Perf]","tdoc_agenda_sort_order":3430,"status":"agreed","reservation_date":"2020-08-07 14:25:49","uploaded":"2020-08-30 10:18:18","revisionof":"","revisedto":"","release":"Rel-16","crspec":"38.133","crspecversion":"16.4.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":1052.0,"crrevision":"","crcategory":"A","tsg_crp":"RP-201512","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_96_e\/Docs\/R4-2011100.zip","group":"R4","meeting":"R4-96-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2011140","title":"CR on UL BWP configuration for RRM test cases R15","source":"Huawei, Hisilicon","contact":"Jing Han","contact-id":47284,"tdoctype":"CR","for":"Agreement","abstract":"The initial UL BWP configuration for RRM test cases is defined to be same as RMSI CORESET. This is confusing because RMSI CORESET is for DL only. Similarly, the dedicated UL BWP configuration is defined to include or not include SSB, while SSB is DL only.","secretary_remarks":"","agenda_item_sort_order":46,"ainumber":"4.8.1","ainame":"General [NR_newRAT-Perf]","tdoc_agenda_sort_order":3440,"status":"revised","reservation_date":"2020-08-07 14:26:17","uploaded":"2020-08-07 15:38:38","revisionof":"","revisedto":"R4-2012068","release":"Rel-15","crspec":"38.133","crspecversion":"15.10.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":1074.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_96_e\/Docs\/R4-2011140.zip","group":"R4","meeting":"R4-96-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2011141","title":"CR on UL BWP configuration for RRM test cases R16","source":"Huawei, Hisilicon","contact":"Jing Han","contact-id":47284,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":46,"ainumber":"4.8.1","ainame":"General [NR_newRAT-Perf]","tdoc_agenda_sort_order":3460,"status":"agreed","reservation_date":"2020-08-07 14:26:18","uploaded":"2020-08-30 10:18:18","revisionof":"","revisedto":"","release":"Rel-16","crspec":"38.133","crspecversion":"16.4.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":1075.0,"crrevision":"","crcategory":"A","tsg_crp":"RP-201512","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_96_e\/Docs\/R4-2011141.zip","group":"R4","meeting":"R4-96-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2012067","title":"Addition of new default configurations for RMC scheduling","source":"Huawei, Hisilicon","contact":"Kai-Erik Sunell","contact-id":74524,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":46,"ainumber":"4.8.1","ainame":"General [NR_newRAT-Perf]","tdoc_agenda_sort_order":3420,"status":"agreed","reservation_date":"2020-08-29 19:40:31","uploaded":"2020-08-30 11:10:48","revisionof":"R4-2011099","revisedto":"","release":"Rel-15","crspec":"38.133","crspecversion":"15.10.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":1051.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"RP-201512","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_96_e\/Docs\/R4-2012067.zip","group":"R4","meeting":"R4-96-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2012068","title":"CR on UL BWP configuration for RRM test cases R15","source":"Huawei, Hisilicon","contact":"Kai-Erik Sunell","contact-id":74524,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":46,"ainumber":"4.8.1","ainame":"General [NR_newRAT-Perf]","tdoc_agenda_sort_order":3450,"status":"agreed","reservation_date":"2020-08-29 19:40:34","uploaded":"2020-08-30 11:10:48","revisionof":"R4-2011140","revisedto":"","release":"Rel-15","crspec":"38.133","crspecversion":"15.10.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":1074.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"RP-201512","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_96_e\/Docs\/R4-2012068.zip","group":"R4","meeting":"R4-96-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0}]