[{"name":"R4-2014394","title":"Discussion on out of band CLTA maximum height","source":"CATT","contact":"Yuexia Song","contact-id":34261,"tdoctype":"discussion","for":"Discussion","abstract":"Observation 1: The availability condition for option 1 is not clear, which may affect the selection of out-of-band CLTA and requirement verification.\n\nObservation 2: For option 1, two candidate out-of-band CLTAs might be available for a specific co-located band, which will result in different out-of-band CLTA selection and different test results. \n\nObservation 3: For option 1, there is the case that no candidate out-of-band CLTA for a specific co-located band is available.\n\nObservation 4: 1.5m height limit could be used as the height limit for option 2.","secretary_remarks":"[97e][303] NR_Conformance_Maintenance","agenda_item_sort_order":33,"ainumber":"4.5.4","ainame":"Radiated conformance testing (38.141-2) [NR_newRAT-Perf]","tdoc_agenda_sort_order":2670,"status":"noted","reservation_date":"2020-10-22 10:25:13","uploaded":"2020-10-23 13:40:51","revisionof":"","revisedto":"","release":"Rel-15","crspec":"","crspecversion":"","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_97_e\/Docs\/R4-2014394.zip","group":"R4","meeting":"R4-97-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2014395","title":"CR for TS 38.141-2: Correction on half-power vertical beam width for the out of band CLTA","source":"CATT","contact":"Yuexia Song","contact-id":34261,"tdoctype":"CR","for":"Agreement","abstract":"When the out of band is much lower than the operating band of test object antenna, the existing half-power vertical beam width definition for the out of band CLTA will result in unrealistic antenna height.","secretary_remarks":"[97e][303] NR_Conformance_Maintenance","agenda_item_sort_order":33,"ainumber":"4.5.4","ainame":"Radiated conformance testing (38.141-2) [NR_newRAT-Perf]","tdoc_agenda_sort_order":2680,"status":"not pursued","reservation_date":"2020-10-22 10:25:13","uploaded":"2020-10-23 13:40:51","revisionof":"","revisedto":"","release":"Rel-15","crspec":"38.141-2","crspecversion":"15.7.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":226.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_97_e\/Docs\/R4-2014395.zip","group":"R4","meeting":"R4-97-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2014396","title":"CR for TS 38.141-2: Correction on half-power vertical beam width for the out of band CLTA","source":"CATT","contact":"Yuexia Song","contact-id":34261,"tdoctype":"CR","for":"Agreement","abstract":"When the out of band is much lower than the operating band of test object antenna, the existing half-power vertical beam width definition for the out of band CLTA will result in unrealistic antenna height.","secretary_remarks":"[97e][303] NR_Conformance_Maintenance","agenda_item_sort_order":33,"ainumber":"4.5.4","ainame":"Radiated conformance testing (38.141-2) [NR_newRAT-Perf]","tdoc_agenda_sort_order":2690,"status":"withdrawn","reservation_date":"2020-10-22 10:25:14","uploaded":"2020-10-23 13:40:51","revisionof":"","revisedto":"","release":"Rel-16","crspec":"38.141-2","crspecversion":"16.5.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":227.0,"crrevision":"","crcategory":"A","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_97_e\/Docs\/R4-2014396.zip","group":"R4","meeting":"R4-97-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2015716","title":"CR to TS 38.141-2: Improvement of out-of-band CLTA characteristics","source":"Ericsson","contact":"Esther Sienkiewicz","contact-id":59234,"tdoctype":"CR","for":"Agreement","abstract":"Correction to the CLTA length","secretary_remarks":"[97e][303] NR_Conformance_Maintenance","agenda_item_sort_order":33,"ainumber":"4.5.4","ainame":"Radiated conformance testing (38.141-2) [NR_newRAT-Perf]","tdoc_agenda_sort_order":2700,"status":"not pursued","reservation_date":"2020-10-23 12:02:16","uploaded":"2020-10-23 15:33:47","revisionof":"","revisedto":"","release":"Rel-15","crspec":"38.141-2","crspecversion":"15.7.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":242.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_97_e\/Docs\/R4-2015716.zip","group":"R4","meeting":"R4-97-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2015717","title":"CR to TS 38.141-2: Improvement of out-of-band CLTA characteristics","source":"Ericsson","contact":"Esther Sienkiewicz","contact-id":59234,"tdoctype":"CR","for":"Agreement","abstract":"Correction to the CLTA length","secretary_remarks":"[97e][303] NR_Conformance_Maintenance","agenda_item_sort_order":33,"ainumber":"4.5.4","ainame":"Radiated conformance testing (38.141-2) [NR_newRAT-Perf]","tdoc_agenda_sort_order":2720,"status":"withdrawn","reservation_date":"2020-10-23 12:02:17","uploaded":null,"revisionof":"","revisedto":"","release":"Rel-16","crspec":"38.141-2","crspecversion":"16.5.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":243.0,"crrevision":"","crcategory":"A","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"","group":"R4","meeting":"R4-97-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2016152","title":"CR to 38.141-2: Annex C correction on frequency range of FR2 TT table  (C.2)","source":"Keysight Technologies UK Ltd","contact":"Takao Miyake","contact-id":76264,"tdoctype":"CR","for":"Agreement","abstract":"During study to prepare MU and TT value in TR 38.817-02 documents, study was conducted up to 40GHz. Also with n259 WI, it was looked at up to 43.5GHz. However, in 38.141-2, TT tables for FR2 Rx was left as frequency range up to upper FR2 range which is not correct because study wasn\u2019t done up to such high frequency. Studied value up to 43.5G should not be applied up to 52.6GHz, it is large enough difference to use existing value. Also, during discussion, it was agreed that MU\/TT study would be conducted when new band will be added.","secretary_remarks":"[97e][303] NR_Conformance_Maintenance","agenda_item_sort_order":33,"ainumber":"4.5.4","ainame":"Radiated conformance testing (38.141-2) [NR_newRAT-Perf]","tdoc_agenda_sort_order":2730,"status":"revised","reservation_date":"2020-10-23 15:55:12","uploaded":"2020-10-23 16:42:58","revisionof":"","revisedto":"R4-2017592","release":"Rel-15","crspec":"38.141-2","crspecversion":"15.7.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":249.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_97_e\/Docs\/R4-2016152.zip","group":"R4","meeting":"R4-97-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2016153","title":"CR to 38.141-2: Annex C correction on frequency range of FR2 TT table  (C.2)","source":"Keysight Technologies UK Ltd","contact":"Takao Miyake","contact-id":76264,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"[97e][303] NR_Conformance_Maintenance","agenda_item_sort_order":33,"ainumber":"4.5.4","ainame":"Radiated conformance testing (38.141-2) [NR_newRAT-Perf]","tdoc_agenda_sort_order":2750,"status":"withdrawn","reservation_date":"2020-10-23 15:55:13","uploaded":null,"revisionof":"","revisedto":"","release":"Rel-16","crspec":"38.141-2","crspecversion":"16.5.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":250.0,"crrevision":"","crcategory":"A","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"","group":"R4","meeting":"R4-97-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2016289","title":"Discussions on TRP procedures","source":"Nokia, Nokia Shanghai Bell","contact":"Anthony Lo","contact-id":82474,"tdoctype":"other","for":"Discussion","abstract":"This contribution discusses the open issue related two TRP measurement procedures, namely two orthogonal cuts with pattern multiplication and beam-based directions. \n\nProposal 1: A numerical form of the TRP integral for the two orthogonal cuts with pattern multiplication is defined to allow computation of TRP estimate from discrete data samples.   \n\nProposal 2: Criteria for determining whether correlation exists before applying the beam-based directions procedure should be added to the TR 37.941 as background information, which are as follows: \n\n(a)\tMaximum radiation of unwanted emissions occurs in the same direction as the wanted signal.\n(b)\tThe main lobe of the wanted signal and the unwanted emissions with respect to the axis of maximum radiation should have the same symmetry. \n(c)\tHPBW in the azimuth and elevation direction for the unwanted emissions should correspond to those of the wanted signal.\n(d)\tThe directivity-beamwidth product of the unwanted emissions should correspond to that for the wanted signal.","secretary_remarks":"[97e][303] NR_Conformance_Maintenance","agenda_item_sort_order":33,"ainumber":"4.5.4","ainame":"Radiated conformance testing (38.141-2) [NR_newRAT-Perf]","tdoc_agenda_sort_order":2770,"status":"noted","reservation_date":"2020-10-23 17:02:37","uploaded":"2020-10-23 18:38:45","revisionof":"","revisedto":"","release":"Rel-15","crspec":"","crspecversion":"","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_97_e\/Docs\/R4-2016289.zip","group":"R4","meeting":"R4-97-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2017587","title":"CR to TS 38.141-2: Improvement of out-of-band CLTA characteristics","source":"Ericsson","contact":"Esther Sienkiewicz","contact-id":59234,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"[97e][303] NR_Conformance_Maintenance","agenda_item_sort_order":33,"ainumber":"4.5.4","ainame":"Radiated conformance testing (38.141-2) [NR_newRAT-Perf]","tdoc_agenda_sort_order":2710,"status":"withdrawn","reservation_date":"2020-11-16 09:40:48","uploaded":null,"revisionof":"","revisedto":"","release":"Rel-15","crspec":"38.141-2","crspecversion":"15.7.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":242.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"","group":"R4","meeting":"R4-97-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2017592","title":"CR to 38.141-2: Annex C correction on frequency range of FR2 TT table  (C.2)","source":"Keysight Technologies UK Ltd","contact":"Takao Miyake","contact-id":76264,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"[97e][303] NR_Conformance_Maintenance","agenda_item_sort_order":33,"ainumber":"4.5.4","ainame":"Radiated conformance testing (38.141-2) [NR_newRAT-Perf]","tdoc_agenda_sort_order":2740,"status":"agreed","reservation_date":"2020-11-16 09:40:51","uploaded":"2020-11-16 17:51:17","revisionof":"R4-2016152","revisedto":"","release":"Rel-15","crspec":"38.141-2","crspecversion":"15.7.0","workitem":[{"winame":"NR_newRAT-Perf"}],"crnumber":249.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"RP-202489","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_97_e\/Docs\/R4-2017592.zip","group":"R4","meeting":"R4-97-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R4-2017655","title":"CR to 38.141-2: Annex C correction on frequency range of FR2 TT table  (C.2)","source":"Keysight Technologies UK Ltd","contact":"Kai-Erik Sunell","contact-id":74524,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"[97e][303] NR_Conformance_Maintenance","agenda_item_sort_order":33,"ainumber":"4.5.4","ainame":"Radiated conformance testing (38.141-2) [NR_newRAT-Perf]","tdoc_agenda_sort_order":2760,"status":"agreed","reservation_date":"2020-11-16 09:40:54","uploaded":"2020-11-16 18:01:13","revisionof":"","revisedto":"","release":"Rel-16","crspec":"38.141-2","crspecversion":"16.5.0","workitem":[{"winame":"TEI16"},{"winame":"NR_newRAT-Perf"}],"crnumber":257.0,"crrevision":"","crcategory":"F","tsg_crp":"RP-202509","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG4_Radio\/TSGR4_97_e\/Docs\/R4-2017655.zip","group":"R4","meeting":"R4-97-e","year":2020,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0}]