[{"name":"R3-185367","title":"Conclusion on Source TEID Reuse for handover","source":"Nokia, Nokia Shanghai Bell","contact":"Philippe Godin","contact-id":68843,"tdoctype":"discussion","for":"Approval","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":40200,"status":"noted","reservation_date":"2018-09-24 13:59:06","uploaded":"2018-09-28 22:14:43","revisionof":"","revisedto":"","release":"Rel-15","crspec":"","crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185367.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185368","title":"(TP for NR BL CR for TS 38.423): Source TEID reuse for handover","source":"Nokia, Nokia Shanghai Bell","contact":"Philippe Godin","contact-id":68843,"tdoctype":"other","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":40300,"status":"noted","reservation_date":"2018-09-24 14:02:21","uploaded":"2018-09-28 22:14:43","revisionof":"","revisedto":"","release":"Rel-15","crspec":38.423,"crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185368.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185369","title":"(TP for NR BL CR for TS 38.463): Source TEID Reuse for handover","source":"Nokia, Nokia Shanghai Bell","contact":"Philippe Godin","contact-id":68843,"tdoctype":"other","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":40400,"status":"noted","reservation_date":"2018-09-24 14:05:48","uploaded":"2018-09-28 22:14:43","revisionof":"","revisedto":"","release":"Rel-15","crspec":38.463,"crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185369.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185370","title":"(TP for NR BL CR for TS 38.413): Source TEID Reuse for handover","source":"Nokia, Nokia Shanghai Bell","contact":"Philippe Godin","contact-id":68843,"tdoctype":"other","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":40500,"status":"noted","reservation_date":"2018-09-24 14:47:32","uploaded":"2018-09-28 22:14:43","revisionof":"","revisedto":"","release":"Rel-15","crspec":38.413,"crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185370.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185899","title":"Support of keeping the DL UP termination point on the RAN-CN interface \u2013 HO and DC aspects","source":"Ericsson, Vodafone","contact":"Martin Israelsson","contact-id":2462,"tdoctype":"discussion","for":"","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":40600,"status":"noted","reservation_date":"2018-09-28 17:19:32","uploaded":"2018-09-29 00:39:52","revisionof":"","revisedto":"","release":"Rel-15","crspec":"","crspecversion":"","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185899.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185900","title":"Support of keeping the DL UP termination point on the RAN-CN interface at handover \u2013 for 36.300","source":"Ericsson","contact":"Martin Israelsson","contact-id":2462,"tdoctype":"draftCR","for":"","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":40700,"status":"available","reservation_date":"2018-09-28 17:19:32","uploaded":"2018-09-29 00:40:07","revisionof":"","revisedto":"","release":"Rel-15","crspec":36.3,"crspecversion":"15.3.0","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185900.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185901","title":"Support of keeping the DL UP termination point on the RAN-CN interface at handover \u2013 for 36.413","source":"Ericsson","contact":"Martin Israelsson","contact-id":2462,"tdoctype":"CR","for":"","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":40800,"status":"available","reservation_date":"2018-09-28 17:19:32","uploaded":"2018-09-29 00:40:07","revisionof":"","revisedto":"R3-186776","release":"Rel-15","crspec":36.413,"crspecversion":"15.3.0","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":1632.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185901.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185902","title":"Support of keeping the DL UP termination point on the RAN-CN interface at handover \u2013 for 36.423","source":"Ericsson","contact":"Martin Israelsson","contact-id":2462,"tdoctype":"CR","for":"","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":40900,"status":"available","reservation_date":"2018-09-28 17:19:33","uploaded":"2018-09-29 00:40:07","revisionof":"","revisedto":"R3-186777","release":"Rel-15","crspec":36.423,"crspecversion":"15.3.0","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":1254.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185902.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185903","title":"Support of keeping the DL UP termination point on the RAN-CN interface at handover \u2013 for 38.300","source":"Ericsson","contact":"Martin Israelsson","contact-id":2462,"tdoctype":"other","for":"","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":41000,"status":"available","reservation_date":"2018-09-28 17:19:33","uploaded":"2018-09-29 00:40:07","revisionof":"","revisedto":"","release":"Rel-15","crspec":38.3,"crspecversion":"","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185903.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185904","title":"Support of keeping the DL UP termination point on the RAN-CN interface at handover \u2013 for 38.413","source":"Ericsson","contact":"Martin Israelsson","contact-id":2462,"tdoctype":"other","for":"","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":41100,"status":"available","reservation_date":"2018-09-28 17:19:33","uploaded":"2018-09-29 00:40:07","revisionof":"","revisedto":"","release":"Rel-15","crspec":38.413,"crspecversion":"","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185904.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185905","title":"Support of keeping the DL UP termination point on the RAN-CN interface at handover \u2013  for 38.423","source":"Ericsson","contact":"Martin Israelsson","contact-id":2462,"tdoctype":"other","for":"","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":41200,"status":"available","reservation_date":"2018-09-28 17:19:33","uploaded":"2018-09-29 00:40:27","revisionof":"","revisedto":"","release":"Rel-15","crspec":38.423,"crspecversion":"","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185905.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185906","title":"Support of keeping the DL UP termination point on the RAN-CN interface at handover \u2013 for 38.463","source":"Ericsson","contact":"Martin Israelsson","contact-id":2462,"tdoctype":"other","for":"","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":41300,"status":"available","reservation_date":"2018-09-28 17:19:33","uploaded":"2018-09-29 00:40:27","revisionof":"","revisedto":"","release":"Rel-15","crspec":38.463,"crspecversion":"","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185906.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185907","title":"Support for keeping a stable PDCP anchor at bearer type change or MN change or SN change","source":"Ericsson","contact":"Martin Israelsson","contact-id":2462,"tdoctype":"other","for":"","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":41400,"status":"available","reservation_date":"2018-09-28 17:19:33","uploaded":"2018-09-29 00:40:27","revisionof":"","revisedto":"","release":"Rel-15","crspec":37.34,"crspecversion":"","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185907.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185908","title":"Support for keeping RAN UP termination at DC \u2013 for 36.423","source":"Ericsson","contact":"Martin Israelsson","contact-id":2462,"tdoctype":"CR","for":"","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":41500,"status":"available","reservation_date":"2018-09-28 17:19:33","uploaded":"2018-09-29 00:40:27","revisionof":"","revisedto":"R3-186778","release":"Rel-15","crspec":36.423,"crspecversion":"15.3.0","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":1255.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185908.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0},
{"name":"R3-185909","title":"Support for keeping a stable PDCP anchor at bearer type change or MN change or SN change","source":"Ericsson","contact":"Martin Israelsson","contact-id":2462,"tdoctype":"other","for":"","abstract":"","secretary_remarks":"","agenda_item_sort_order":147,"ainumber":"31.3.1.31","ainame":"Reusing Source TEID at Handover","tdoc_agenda_sort_order":41600,"status":"available","reservation_date":"2018-09-28 17:19:34","uploaded":"2018-09-29 00:40:27","revisionof":"","revisedto":"","release":"Rel-15","crspec":38.423,"crspecversion":"","workitem":[{"winame":"NR_newRAT-Core"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"http:\/\/www.3gpp.org\/ftp\/TSG_RAN\/WG3_Iu\/TSGR3_101bis\/Docs\/R3-185909.zip","group":"R3","meeting":"R3-101","year":2018,"uicc_affected":null,"me_affected":null,"ran_affected":null,"cn_affected":null,"clauses_affected":null,"crsinpack":null,"crsinpacknumber":0}]