[{"name":"C3-253064","title":"PCEF failure or restart detection by PCRF","source":"ZTE","contact":"Shuang Liang","contact-id":60555,"tdoctype":"CR","for":"Agreement","abstract":"The PCRF may detect the PCEF failure or restart based on failures of installation\/activation of one or more PCC rules or no acknowledge received from the PCEF.","secretary_remarks":"Source modified on 8\/18\/2025. Original source : ZTE","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"postponed","reservation_date":"2025-08-18 03:21:29","uploaded":"2025-08-18 09:14:07","revisionof":"","revisedto":"","release":"Rel-19","crspec":29.212,"crspecversion":"18.2.0","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":1718.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG3_interworking_ex-CN3\/TSGC3_142_Goteborg\/Docs\/C3-253064.zip","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"4.5.12","crsinpack":null,"crsinpacknumber":0},
{"name":"C3-253065","title":"Add a new condition for the PCRF detecting PCEF failure in time","source":"ZTE","contact":"Shuang Liang","contact-id":60555,"tdoctype":"CR","for":"Agreement","abstract":"Add a new condition for the PCRF provision PCC\/QoS rules based on the service information derived from the SDP offer.","secretary_remarks":"Source modified on 8\/18\/2025. Original source : ZTE","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"revised","reservation_date":"2025-08-18 03:21:35","uploaded":"2025-08-18 09:14:07","revisionof":"","revisedto":"C3-253505","release":"Rel-19","crspec":29.213,"crspecversion":"19.1.0","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":751.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG3_interworking_ex-CN3\/TSGC3_142_Goteborg\/Docs\/C3-253065.zip","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"B.2.2","crsinpack":null,"crsinpacknumber":0},
{"name":"C3-253066","title":"Add a condition of sending ASR","source":"ZTE","contact":"Shuang Liang","contact-id":60555,"tdoctype":"CR","for":"Agreement","abstract":"The PCRF may detect the PCEF failure or restart during unsuccessful resource allocation for one or more PCC rules at the PCEF and then send an ASR command to the AF session with the Abort-Cause AVP","secretary_remarks":"Source modified on 8\/18\/2025. Original source : ZTE","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"revised","reservation_date":"2025-08-18 03:21:35","uploaded":"2025-08-18 09:14:07","revisionof":"","revisedto":"C3-253676","release":"Rel-19","crspec":29.214,"crspecversion":"19.1.0","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":1700.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG3_interworking_ex-CN3\/TSGC3_142_Goteborg\/Docs\/C3-253066.zip","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"4.4.6.2, 5.3.1","crsinpack":null,"crsinpacknumber":0},
{"name":"C3-253067","title":"SMF failure or restart detection by PCF","source":"ZTE","contact":"Shuang Liang","contact-id":60555,"tdoctype":"CR","for":"Agreement","abstract":"The PCF may detect the NF consumer failure or restart based on failures of installation\/activation of one or more PCC rules or no acknowledge received from the NF consumer","secretary_remarks":"Source modified on 8\/18\/2025. Original source : ZTE","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"postponed","reservation_date":"2025-08-18 03:21:36","uploaded":"2025-08-18 09:14:07","revisionof":"","revisedto":"","release":"Rel-19","crspec":29.512,"crspecversion":"19.3.0","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":1387.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG3_interworking_ex-CN3\/TSGC3_142_Goteborg\/Docs\/C3-253067.zip","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"4.2.3.xx(new)","crsinpack":null,"crsinpacknumber":0},
{"name":"C3-253068","title":"Add a new condition for the PCF detecting PCEF failure in time","source":"ZTE","contact":"Shuang Liang","contact-id":60555,"tdoctype":"CR","for":"Agreement","abstract":"Add a new condition for the PCF provision PCC rules based on the service information derived from the SDP offer.","secretary_remarks":"Source modified on 8\/18\/2025. Original source : ZTE","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"revised","reservation_date":"2025-08-18 03:21:36","uploaded":"2025-08-18 09:14:07","revisionof":"","revisedto":"C3-253506","release":"Rel-19","crspec":29.513,"crspecversion":"19.3.0","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":605.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG3_interworking_ex-CN3\/TSGC3_142_Goteborg\/Docs\/C3-253068.zip","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"B.2.2","crsinpack":null,"crsinpacknumber":0},
{"name":"C3-253069","title":"Add a condition of invoking Npcf_PolicyAuthorization_Notify","source":"ZTE","contact":"Shuang Liang","contact-id":60555,"tdoctype":"CR","for":"Agreement","abstract":"Add a new condition for the PCF to invoke Npcf_PolicyAuthorization_Notify to the service comsumer (i.e. P-CSCF) when the PCF detects the CN NF (e.g. SMF) failure or restart during unsuccessful resource allocation for one or more PCC rules.","secretary_remarks":"Source modified on 8\/18\/2025. Original source : ZTE","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"revised","reservation_date":"2025-08-18 03:21:37","uploaded":"2025-08-18 09:14:07","revisionof":"","revisedto":"C3-253677","release":"Rel-19","crspec":29.514,"crspecversion":"19.3.0","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":776.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG3_interworking_ex-CN3\/TSGC3_142_Goteborg\/Docs\/C3-253069.zip","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"4.2.5.1, 4.2.5.xx(new), 5.6.3.10, 5.8, A.2, B.1","crsinpack":null,"crsinpacknumber":0},
{"name":"C3-253116","title":"Procedure of EPC NF failure checking","source":"Huawei","contact":"Mengdi Ji","contact-id":75038,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"withdrawn","reservation_date":"2025-08-18 08:18:45","uploaded":null,"revisionof":"","revisedto":"","release":"Rel-19","crspec":29.214,"crspecversion":"19.1.0","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":1701.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"C3-253117","title":"Procedure of 5GC NF failure checking","source":"Huawei","contact":"Mengdi Ji","contact-id":75038,"tdoctype":"CR","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"withdrawn","reservation_date":"2025-08-18 08:21:03","uploaded":null,"revisionof":"","revisedto":"","release":"Rel-19","crspec":29.514,"crspecversion":"19.3.0","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":779.0,"crrevision":"","crcategory":"B","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"C3-253505","title":"Add a new condition for the PCRF detecting PCEF failure in time","source":"ZTE, Ericsson","contact":"Shuang Liang","contact-id":60555,"tdoctype":"CR","for":"Agreement","abstract":"Add a new condition for the PCRF provision PCC\/QoS rules based on the service information derived from the SDP offer.","secretary_remarks":"","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"agreed","reservation_date":"2025-08-26 16:38:28","uploaded":"2025-09-06 00:01:11","revisionof":"C3-253065","revisedto":"","release":"Rel-19","crspec":29.213,"crspecversion":"19.1.0","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":751.0,"crrevision":1.0,"crcategory":"B","tsg_crp":"CP-252086","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG3_interworking_ex-CN3\/TSGC3_142_Goteborg\/Docs\/C3-253505.zip","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"C3-253506","title":"Add a new condition for the PCF detecting PCEF failure in time","source":"ZTE, Ericsson","contact":"Shuang Liang","contact-id":60555,"tdoctype":"CR","for":"Agreement","abstract":"Add a new condition for the PCF provision PCC rules based on the service information derived from the SDP offer.","secretary_remarks":"","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"agreed","reservation_date":"2025-08-26 16:38:50","uploaded":"2025-09-06 00:01:11","revisionof":"C3-253068","revisedto":"","release":"Rel-19","crspec":29.513,"crspecversion":"19.3.0","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":605.0,"crrevision":1.0,"crcategory":"B","tsg_crp":"CP-252086","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG3_interworking_ex-CN3\/TSGC3_142_Goteborg\/Docs\/C3-253506.zip","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"C3-253676","title":"Add a condition of sending ASR","source":"ZTE, Ericsson","contact":"Shuang Liang","contact-id":60555,"tdoctype":"CR","for":"Agreement","abstract":"The PCRF may detect the PCEF failure or restart during unsuccessful resource allocation for one or more PCC rules at the PCEF and then send an ASR command to the AF session with the Abort-Cause AVP","secretary_remarks":"","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"agreed","reservation_date":"2025-08-28 17:11:33","uploaded":"2025-09-06 00:01:13","revisionof":"C3-253066","revisedto":"","release":"Rel-19","crspec":29.214,"crspecversion":"19.1.0","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":1700.0,"crrevision":1.0,"crcategory":"B","tsg_crp":"CP-252086","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG3_interworking_ex-CN3\/TSGC3_142_Goteborg\/Docs\/C3-253676.zip","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"C3-253677","title":"Add a condition of invoking Npcf_PolicyAuthorization_Notify","source":"ZTE, Ericsson","contact":"Shuang Liang","contact-id":60555,"tdoctype":"CR","for":"Agreement","abstract":"Add a new condition for the PCF to invoke Npcf_PolicyAuthorization_Notify to the service comsumer (i.e. P-CSCF) when the PCF detects the CN NF (e.g. SMF) failure or restart during unsuccessful resource allocation for one or more PCC rules.","secretary_remarks":"","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"agreed","reservation_date":"2025-08-28 17:11:48","uploaded":"2025-09-06 00:01:13","revisionof":"C3-253069","revisedto":"","release":"Rel-19","crspec":29.514,"crspecversion":"19.3.0","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":776.0,"crrevision":1.0,"crcategory":"B","tsg_crp":"CP-252086","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG3_interworking_ex-CN3\/TSGC3_142_Goteborg\/Docs\/C3-253677.zip","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"C3-253715","title":"Exception sheet for IMS_RES-CT","source":"China Telecom","contact":"Yue Sun","contact-id":83723,"tdoctype":"WI exception request","for":"Agreement","abstract":"","secretary_remarks":"","agenda_item_sort_order":282,"ainumber":"19.67","ainame":"IMS Disaster Prevention and Restoration Enhancement [IMS_RES-CT]","tdoc_agenda_sort_order":0,"status":"agreed","reservation_date":"2025-08-29 14:54:40","uploaded":"2025-09-06 00:01:13","revisionof":"","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"IMS_RES-CT"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_ct\/WG3_interworking_ex-CN3\/TSGC3_142_Goteborg\/Docs\/C3-253715.zip","group":"C3","meeting":"C3-142","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0}]