[{"name":"S2-2508176","title":"LS from CT WG3: LS out on clarification on threshold-based reporting","source":"CT WG3","contact":"Bhaskar Paul","contact-id":99427,"tdoctype":"LS in","for":"Action","abstract":"In TS 23.501 clause 5.51.2.4: The consumer NF may also subscribe the above information exposure with providing reporting period, or time window. AF\/NEF may also subscribe the Energy consumption information exposure of required granularity and may provide reporting threshold for the required granularity and the reporting time period. NOTE 1: For the threshold-based reporting, the EIF sends the Energy consumption information of the required granularity to the NEF\/AF once when the Energy consumption information of the required granularity matches or exceeds the threshold during the reporting time period. CT WG3 would like to ask the following questions to SA WG2: Questions: 1. Whether the 'reporting time period' and 'reporting period' mentioned in the above clause are the same definition (i.e. every reporting period of e.g. 10 minutes)? 2. For threshold-based reporting subscription, whether the 'reporting period' (i.e. every reporting period of e.g. 10 minutes) or 'time window' (i.e. from a start time to an end time) shall be provided with reporting threshold for the required granularity?. Action: CT WG3 kindly ask SA WG2 to clarify the above questions and update SA WG2 specification if needed.","secretary_remarks":"Responses drafted in S2-2508381, S2-2508425, S2-2508631, S2-2508801. Agreed response in S2-2509467. Final response in S2-2509467.","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":12930,"status":"replied to","reservation_date":"2025-09-25 06:30:45","uploaded":"2025-09-25 14:28:34","revisionof":"","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":"","crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"SA WG2","Cc":"","lsoriginalls":"C3-253702","lsreply":"S2-2509467","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508176.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508323","title":"EIF discovery and selection to avoid duplicated OAM interaction","source":"Samsung","contact":"Dongeun Suh","contact-id":84836,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Consumer NF discovers\/selects EIF based on SUPI or GPSI (for NEF)","secretary_remarks":"Revision of (Unhandled) S2-2506713. Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13320,"status":"not treated","reservation_date":"2025-09-29 00:28:05","uploaded":"2025-10-01 07:38:16","revisionof":"S2-2506713","revisedto":"S2-2510351","release":"Rel-19","crspec":"23.502","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":5540.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508323.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508324","title":"EIF discovery and selection to avoid duplicated OAM interaction","source":"Samsung","contact":"Dongeun Suh","contact-id":84836,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Consumer NF discovers\/selects EIF based on SUPI or GPSI (for NEF)","secretary_remarks":"Revision of (Unhandled) S2-2506710. Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13330,"status":"not treated","reservation_date":"2025-09-29 00:30:56","uploaded":"2025-10-01 07:47:34","revisionof":"S2-2506710","revisedto":"S2-2510350, S2-2510352","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6372.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508324.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"6.3.27","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508381","title":"[DRAFT] LS Reply on clarification on threshold-based reporting","source":"vivo","contact":"Zhuoyun Zhang","contact-id":106952,"tdoctype":"LS out","for":"Approval","abstract":"To: CT WG3. Attachments: 23.501 CR6429.","secretary_remarks":"Response to S2-2508176. Revised in parallel session to S2-2509369.","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":12940,"status":"revised","reservation_date":"2025-09-30 01:16:51","uploaded":"2025-10-03 15:01:24","revisionof":"","revisedto":"S2-2509369","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"EnergySys"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"CT WG3","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508381.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508382","title":"Clarification on threshold-based reporting for energy consumption information exposure","source":"Vivo","contact":"Zhuoyun Zhang","contact-id":106952,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: In clause 5.51.2.4, it is proposed to clarify that the 'time window' needs to be provided with reporting threshold for threshold-based reporting. There is no need to provide reporting period for threshold-based reporting for energy consumption information exposure. In NOTE2, the 'reporting time period' is changed to 'reporting period' for alignment.","secretary_remarks":"Merged into S2-2509466","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13050,"status":"merged","reservation_date":"2025-09-30 01:20:23","uploaded":"2025-10-03 15:01:24","revisionof":"","revisedto":"","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6429.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508382.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.51.2.4","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508425","title":"[DRAFT] Reply LS on clarification on threshold-based reporting","source":"Qualcomm Atheros, Inc.","contact":"Juan Zhang","contact-id":73274,"tdoctype":"LS out","for":"Approval","abstract":"To: CT WG3","secretary_remarks":"Response to S2-2508176. Merged into S2-2509467","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":12980,"status":"merged","reservation_date":"2025-09-30 06:25:17","uploaded":"2025-10-03 09:56:17","revisionof":"","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"EnergySys"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"CT WG3","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508425.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508426","title":"Clarification on threshold-based reporting","source":"Qualcomm Incorporated","contact":"Juan Zhang","contact-id":73274,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarify that the AF may provide reporting threshold together with the reporting period, or time window.","secretary_remarks":"Check WI Code Capitalization! Merged into S2-2509466","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13060,"status":"merged","reservation_date":"2025-09-30 06:27:34","uploaded":"2025-10-03 09:56:17","revisionof":"","revisedto":"","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6430.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508426.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508562","title":"Clarifications on energy consumption information for replaced PDU session","source":"Samsung","contact":"Dongeun Suh","contact-id":84836,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: SMF terminates the subscription related to the PDU session if the S-NSSAI of the PDU session is replaced","secretary_remarks":"Revised in parallel session to S2-2509373.","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13200,"status":"revised","reservation_date":"2025-10-01 07:27:21","uploaded":"2025-10-01 07:51:12","revisionof":"","revisedto":"S2-2509373","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6435.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508562.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.51.2.2.2","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508563","title":"Clarifications on energy consumption information for replaced PDU session","source":"Samsung","contact":"Dongeun Suh","contact-id":84836,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: SMF terminates the subscription related to the PDU session if the S-NSSAI of the PDU session is replaced","secretary_remarks":"Noted in parallel session","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13240,"status":"noted","reservation_date":"2025-10-01 07:28:23","uploaded":"2025-10-01 07:50:17","revisionof":"","revisedto":"","release":"Rel-19","crspec":"23.502","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":5583.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508563.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"4.29.2","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508631","title":"[DRAFT] Reply LS on clarification on threshold-based reporting","source":"Nokia","contact":"Alessio Casati","contact-id":82456,"tdoctype":"LS out","for":"Approval","abstract":"To: CT WG3. Attachments: 23.501 CR 6341.","secretary_remarks":"Response to S2-2508176. Merged into S2-2509467","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":12990,"status":"merged","reservation_date":"2025-10-01 18:00:51","uploaded":"2025-10-03 08:54:28","revisionof":"","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"EnergySys"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"CT WG3","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508631.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508632","title":"Clarification on exposure of energy consumption threshold by EIF","source":"Nokia","contact":"Alessio Casati","contact-id":82456,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: It is clarified that if the consumption threshold is not crossed, the EIF reports no consumption information for the time period. Text is also made a bit clearer for the reader on what 'future' means. NF is replaced with AF\/NEF as these are the expected consumers in rel-19.","secretary_remarks":"Revision of  (Unhandled) S2-2506239.  Confirm CR Number - CR states -6341! Revised in parallel session to S2-2509368.","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13010,"status":"revised","reservation_date":"2025-10-01 18:05:36","uploaded":"2025-10-03 08:54:28","revisionof":"S2-2506239","revisedto":"S2-2509368","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6341.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508632.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508634","title":"Discussion on overlapping Predefined PDRs.","source":"Nokia","contact":"Alessio Casati","contact-id":82456,"tdoctype":"discussion","for":"Agreement","abstract":"Discussion on overlapping Predefined PDRs.","secretary_remarks":"Noted in parallel session","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13190,"status":"noted","reservation_date":"2025-10-01 18:11:13","uploaded":"2025-10-03 08:54:28","revisionof":"","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"EnergySys"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508634.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508635","title":"Clarification on handling of application ID\/predefined PDRs in reporting of usage data volume to EIF- option SMF is aware of App ID","source":"Nokia","contact":"Alessio Casati","contact-id":82456,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarify the solution assumes that the SMF can be Application ID semantics aware.","secretary_remarks":"Revised in parallel session to S2-2509372.","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13130,"status":"revised","reservation_date":"2025-10-01 18:20:44","uploaded":"2025-10-03 08:54:28","revisionof":"","revisedto":"S2-2509372","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6438.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508635.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508636","title":"Clarification on handling of application ID\/predefined PDRs in reporting of usage data volume to EIF - Removal of SDF\/Application ID level option","source":"Nokia","contact":"Alessio Casati","contact-id":82456,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Removal of the SDF\/Applciation ID level exposure.","secretary_remarks":"Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13170,"status":"not treated","reservation_date":"2025-10-01 18:52:49","uploaded":"2025-10-03 08:54:28","revisionof":"","revisedto":"","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6439.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508636.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508638","title":"Clarification on handling of application ID\/predefined PDRs in reporting of usage data volume to EIF - Removal of SDF\/Application ID level option","source":"Nokia","contact":"Alessio Casati","contact-id":82456,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Removal of the SDF\/Applciation ID level exposure.","secretary_remarks":"Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13180,"status":"not treated","reservation_date":"2025-10-01 19:05:27","uploaded":"2025-10-03 08:54:28","revisionof":"","revisedto":"","release":"Rel-19","crspec":"23.502","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":5586.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508638.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508750","title":"Clarification on Energy Consumption Estimation Formula","source":"NTT DOCOMO","contact":"Bahador Bakhshi","contact-id":98273,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Adding a NOTE to clarify that the EC estimation formula may provide different estimations for the same volume of transmitted data.","secretary_remarks":"Check Affected Clauses! Revised in parallel session to S2-2509371.","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13100,"status":"revised","reservation_date":"2025-10-02 07:07:56","uploaded":"2025-10-02 19:11:15","revisionof":"","revisedto":"S2-2509371","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6446.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508750.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508756","title":"Clarification of the lack of supporting EC when DC is used","source":"Huawei, HiSilicon","contact":"Marco Spini","contact-id":8356,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarify that UE related Energy Consumption information does not consider the secondary RAT when DC is activated.","secretary_remarks":"Revision of  (Unhandled) S2-2506702. Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13250,"status":"not treated","reservation_date":"2025-10-02 07:22:20","uploaded":"2025-10-03 12:18:19","revisionof":"S2-2506702","revisedto":"S2-2510729","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6321.0,"crrevision":2.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508756.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.51.2.1","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508757","title":"Correction on Energy Consumption calculation in case of redundant transmission or PDU Session with multiple PDU Session Anchors","source":"Huawei, HiSilicon","contact":"Marco Spini","contact-id":8356,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Add the description on how does the SMF handle data volume reported from UPF in case of redundant transmission or PDU Session with multiple UPF Anchors and provide it to EIF. E.g., when redundant transmission is used, the data volume provided to EIF shall also include the duplicated traffic. Add an optional entry NF specific UL and\/or DL Data Volume in the Information from SMF for user-plane energy consumption calculation.","secretary_remarks":"Revision of  (Unhandled) S2-2507313. Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13260,"status":"not treated","reservation_date":"2025-10-02 07:22:21","uploaded":"2025-10-03 12:18:19","revisionof":"S2-2507313","revisedto":"S2-2510727","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6411.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508757.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.51.2.2","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508801","title":"[DRAFT] Reply LS out on clarification on threshold-based reporting","source":"ZTE","contact":"Zhendong Li","contact-id":38521,"tdoctype":"LS out","for":"Approval","abstract":"Proposes a Reply LS out on clarification on threshold-based reportingo","secretary_remarks":"Response to S2-2508176. Merged into S2-2509467","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13000,"status":"merged","reservation_date":"2025-10-02 13:19:47","uploaded":"2025-10-03 11:55:59","revisionof":"","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"EnergySys"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"CT WG3","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508801.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508802","title":"Clarification on the Energy exposure","source":"ZTE","contact":"Zhendong Li","contact-id":38521,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarifying Node description and reporting time condition.","secretary_remarks":"Revision of  (Unhandled) S2-2507110. Revised in parallel session to S2-2509370.","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13070,"status":"revised","reservation_date":"2025-10-02 13:19:47","uploaded":"2025-10-03 11:55:59","revisionof":"S2-2507110","revisedto":"S2-2509370","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6396.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508802.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.51.2.2.1, 5.51.2.4","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508803","title":"Clarifying Nsmf_PDUSession_Update service operation on ULI","source":"ZTE","contact":"Zhendong Li","contact-id":38521,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarifying Nsmf_PDUSession_Update service operation on ULI reporting","secretary_remarks":"Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13280,"status":"not treated","reservation_date":"2025-10-02 13:19:48","uploaded":"2025-10-03 11:55:59","revisionof":"","revisedto":"S2-2510188","release":"Rel-19","crspec":"23.502","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":5591.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508803.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.2.8.2.3","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508804","title":"Clarification on the EIF functionality","source":"ZTE","contact":"Zhendong Li","contact-id":38521,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Correct the energy calculation","secretary_remarks":"Revision of  (Unhandled) S2-2507111. Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13340,"status":"not treated","reservation_date":"2025-10-02 13:19:49","uploaded":"2025-10-03 11:55:59","revisionof":"S2-2507111","revisedto":"S2-2510189","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6397.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508804.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"6.2.34","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508805","title":"Correction to EIF Event Exposure service","source":"ZTE","contact":"Zhendong Li","contact-id":38521,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Correct reference clause and event filter description.","secretary_remarks":"Revision of  (Unhandled) S2-2507112. Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13350,"status":"not treated","reservation_date":"2025-10-02 13:19:50","uploaded":"2025-10-03 11:55:59","revisionof":"S2-2507112","revisedto":"S2-2510190","release":"Rel-19","crspec":"23.502","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":5558.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508805.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.2.28.2.1, 5.2.28.2.2","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508887","title":"Energy Consumption information collection from SMF.","source":"Ericsson","contact":"Shabnam Sultana","contact-id":21207,"tdoctype":"discussion","for":"Discussion","abstract":"UPF Event Exposure can be used for information collection by SMF for Energy Consumption with no impact on PCC Rules.","secretary_remarks":"Revision of (Noted) S2-2506407. Noted in parallel session","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13310,"status":"noted","reservation_date":"2025-10-02 15:53:33","uploaded":"2025-10-03 19:41:44","revisionof":"S2-2506407","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"EnergySys"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508887.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508888","title":"Correction of Energy Consumption Information collection from SMF","source":"Ericsson","contact":"Shabnam Sultana","contact-id":21207,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: SMF subscribes to Nupf_EventExposure for Data volume information instead of sending and N4 Session Update which is complex, incompatible with optimizations like predefined rules, and not guaranteed to deliver what EIF needs (see DP S2-2508887). The Energy Consumption information reported to the EIF shall be time-aligned. So, not only the period duration but the period start times are relevant. The periodic Volume measurements and reporting can be requested to UPF with network-wide configured starting time and interval T for calculation of energy consumption (see TS 23.501 clause 5.51). UPF can be requested the measurement at data path change. For MA PDU Sessions, UPF can be requested the measurement per access. For Service Data Flow granularity, Application Id or Flow Info (packet filters) can be received in SMF.","secretary_remarks":"Revision of  (Postponed) S2-2506408. Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13290,"status":"not treated","reservation_date":"2025-10-02 15:53:33","uploaded":"2025-10-03 19:41:44","revisionof":"S2-2506408","revisedto":"","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6353.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508888.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.51.2.2.2","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508889","title":"Correction of Energy Consumption Information collection from SMF","source":"Ericsson","contact":"Shabnam Sultana","contact-id":21207,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: SMF subscribes to Nupf_EventExposure for Data volume information instead of sending and N4 Session Update which is complex, incompatible with optimizations like predefined rules, and not guaranteed to deliver what EIF needs (see DP S2-2508887). The Energy Consumption information reported to the EIF shall be time-aligned. So, not only the period duration but the period start times are relevant. The periodic Volume measurements and reporting can be requested to UPF with network-wide configured starting time and interval T for calculation of energy consumption (see TS 23.501 clause 5.51). UPF can be requested to report the volume measurement at data path change. UPF can be requested to report the volume measurement per access for Multi-access PDU sessions.","secretary_remarks":"Revision of  (Unhandled) S2-2506409. Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13300,"status":"not treated","reservation_date":"2025-10-02 15:53:35","uploaded":"2025-10-03 19:41:44","revisionof":"S2-2506409","revisedto":"","release":"Rel-19","crspec":"23.502","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":5523.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508889.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"4.15.4.5.1, 4.15.4.5.x (new), 4.29.2, 5.2.8.3.3, 5.2.26.2.1, 5.2.26.2.3","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2508890","title":"Corrections to Non-3GPP Access reporting","source":"Ericsson","contact":"Shabnam Sultana","contact-id":21207,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarify that the SMF shall not collect\/report data volume when the PDU Session is over Non-3GPP Access type, or it is a PDN connection over EPS handled at a SMF+PGW-C in clause 5.51.2.2.2. Correct PDU session as PDU Session in clause 5.51.2.2.2.","secretary_remarks":"Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13270,"status":"not treated","reservation_date":"2025-10-02 15:53:36","uploaded":"2025-10-03 19:41:44","revisionof":"","revisedto":"S2-2510230","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6450.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2508890.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.51.2.2.2","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509258","title":"Clarification on user consent for energy-based policy","source":"Samsung","contact":"Jungshin Park","contact-id":65750,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: User consent is added to the energy-based policy modification.","secretary_remarks":"Corrupt docx file. Replaced on FTP. Not Handled","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13360,"status":"not treated","reservation_date":"2025-10-03 21:23:04","uploaded":"2025-10-03 21:24:54","revisionof":"","revisedto":"","release":"Rel-19","crspec":"23.503","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":1588.0,"crrevision":"","crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509258.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509368","title":"Clarification on exposure of energy consumption threshold by EIF","source":"Nokia, Vivo","contact":"Alessio Casati","contact-id":82456,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: It is clarified that if the consumption threshold is not crossed, the EIF reports no consumption information for the time period. Text is also made a bit clearer for the reader on what 'future' means. NF is replaced with AF\/NEF as these are the expected consumers in rel-19.","secretary_remarks":"Revision of S2-2508632. Revised to S2-2509420","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13020,"status":"revised","reservation_date":"2025-10-14 05:45:11","uploaded":"2025-10-20 16:11:06","revisionof":"S2-2508632","revisedto":"S2-2509420","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6341.0,"crrevision":2.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509368.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509369","title":"[DRAFT] LS Reply on clarification on threshold-based reporting","source":"vivo","contact":"Zhuoyun Zhang","contact-id":106952,"tdoctype":"LS out","for":"Approval","abstract":"To: CT WG3. Attachments: 23.501 CR6429.","secretary_remarks":"Revision of S2-2508381. Revised to S2-2509421.","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":12950,"status":"revised","reservation_date":"2025-10-14 05:45:12","uploaded":"2025-10-20 16:11:06","revisionof":"S2-2508381","revisedto":"S2-2509421","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"EnergySys"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"CT WG3","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509369.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509370","title":"Clarification on the Energy exposure","source":"ZTE","contact":"Zhendong Li","contact-id":38521,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarifying Node description.","secretary_remarks":"Revision of S2-2508802. Revised to S2-2509422.","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13080,"status":"revised","reservation_date":"2025-10-14 05:45:12","uploaded":"2025-10-20 16:11:06","revisionof":"S2-2508802","revisedto":"S2-2509422","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6396.0,"crrevision":2.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509370.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.51.2.2.1","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509371","title":"Clarification on Energy Consumption Estimation Formula","source":"NTT DOCOMO","contact":"Bahador Bakhshi","contact-id":98273,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Adding a NOTE to clarify that the EC estimation formula may provide different estimations for the same volume of transmitted data.","secretary_remarks":"Revision of S2-2508750. Revised to S2-2509423.","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13110,"status":"revised","reservation_date":"2025-10-14 05:45:13","uploaded":"2025-10-20 16:11:06","revisionof":"S2-2508750","revisedto":"S2-2509423","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6446.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509371.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509372","title":"Clarification on handling of application ID\/predefined PDRs in reporting of usage data volume to EIF- option SMF is aware of App ID","source":"Nokia","contact":"Alessio Casati","contact-id":82456,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarify the solution assumes that the SMF can be Application ID semantics aware.","secretary_remarks":"Revision of S2-2508635. Revised to S2-2509424","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13140,"status":"revised","reservation_date":"2025-10-14 05:45:14","uploaded":"2025-10-20 16:11:06","revisionof":"S2-2508635","revisedto":"S2-2509424","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6438.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509372.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509373","title":"Clarifications on energy consumption information for replaced PDU session","source":"Samsung","contact":"Dongeun Suh","contact-id":84836,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: SMF terminates the subscription related to the PDU session if the S-NSSAI of the PDU session is replaced","secretary_remarks":"Revision of S2-2508562. Revised to S2-2509425.","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13210,"status":"revised","reservation_date":"2025-10-14 05:45:15","uploaded":"2025-10-20 16:11:06","revisionof":"S2-2508562","revisedto":"S2-2509425","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6435.0,"crrevision":1.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509373.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509420","title":"Clarification on exposure of energy consumption threshold by EIF","source":"Nokia","contact":"Alessio Casati","contact-id":82456,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: It is clarified that if the consumption threshold is not crossed, the EIF reports no consumption information for the period. Text is also made a bit clearer for the reader on what 'future' means. NF is replaced with AF\/NEF as these are the expected consumers in rel-19.","secretary_remarks":"Revision of S2-2509368. Revised in parallel session to S2-2509466, merging S2-2508426 and S2-2508382","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13030,"status":"revised","reservation_date":"2025-10-16 05:35:53","uploaded":"2025-10-20 16:11:08","revisionof":"S2-2509368","revisedto":"S2-2509466","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6341.0,"crrevision":3.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509420.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509421","title":"[DRAFT] LS Reply on clarification on threshold-based reporting","source":"vivo","contact":"Zhuoyun Zhang","contact-id":106952,"tdoctype":"LS out","for":"Approval","abstract":"To: CT WG3. Attachments: 23.501 CR6429.","secretary_remarks":"Revision of S2-2509369. Revised in parallel session to S2-2509467, merging S2-2508801, S2-2508631 and S2-2508425","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":12960,"status":"revised","reservation_date":"2025-10-16 05:35:54","uploaded":"2025-10-20 16:11:08","revisionof":"S2-2509369","revisedto":"S2-2509467","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"EnergySys"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"","lsto":"CT WG3","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509421.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509422","title":"Clarification on the Energy exposure","source":"ZTE","contact":"Zhendong Li","contact-id":38521,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarifying Node description.","secretary_remarks":"Revision of S2-2509370. Agreed in parallel session. Block approved","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13090,"status":"agreed","reservation_date":"2025-10-16 05:35:54","uploaded":"2025-10-20 16:11:08","revisionof":"S2-2509370","revisedto":"","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6396.0,"crrevision":3.0,"crcategory":"F","tsg_crp":"SP-251330","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509422.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.51.2.2.1","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509423","title":"Clarification on Energy Consumption Estimation Formula","source":"NTT DOCOMO","contact":"Bahador Bakhshi","contact-id":98273,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Adding a NOTE to clarify that the EC estimation formula may provide different estimations for the same volume of transmitted data.","secretary_remarks":"Revision of S2-2509371. Agreed. Block approved","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13120,"status":"agreed","reservation_date":"2025-10-16 05:35:54","uploaded":"2025-10-20 16:11:08","revisionof":"S2-2509371","revisedto":"","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6446.0,"crrevision":2.0,"crcategory":"F","tsg_crp":"SP-251330","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509423.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509424","title":"Clarification on handling of application ID\/predefined PDRs in reporting of usage data volume to EIF- option SMF is aware of App ID","source":"Nokia, Huawei","contact":"Alessio Casati","contact-id":82456,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarify the solution assumes that the SMF can be Application ID semantics aware.","secretary_remarks":"Revision of S2-2509372. Revised in parallel session to S2-2509647 (withdrawn). Postponed","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13150,"status":"postponed","reservation_date":"2025-10-16 05:35:55","uploaded":"2025-10-20 16:11:08","revisionof":"S2-2509372","revisedto":"S2-2509647, S2-2510163","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6438.0,"crrevision":2.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509424.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509425","title":"Clarifications on energy consumption information for replaced PDU session","source":"Samsung","contact":"Dongeun Suh","contact-id":84836,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarifications on the SMF reporting to the EIF in case of the network slice replacement","secretary_remarks":"Revision of S2-2509373. Revised in parallel session to S2-2509648.","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13220,"status":"revised","reservation_date":"2025-10-16 05:35:56","uploaded":"2025-10-20 16:11:08","revisionof":"S2-2509373","revisedto":"S2-2509648","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6435.0,"crrevision":2.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509425.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.51.2.2.2","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509466","title":"Clarification on exposure of energy consumption threshold by EIF","source":"Nokia","contact":"Alessio Casati","contact-id":82456,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: It is clarified that if the consumption threshold is not crossed, the EIF reports no consumption information for the period. Text is also made a bit clearer for the reader on what 'future' means. NF is replaced with AF\/NEF as these are the expected consumers in rel-19.","secretary_remarks":"Revision of S2-2509420. Agreed in parallel session, merging S2-2508426 and S2-2508382. Block approved","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13040,"status":"agreed","reservation_date":"2025-10-20 13:06:54","uploaded":"2025-10-20 16:11:09","revisionof":"S2-2509420","revisedto":"","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6341.0,"crrevision":4.0,"crcategory":"F","tsg_crp":"SP-251330","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509466.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509467","title":"LS Reply on clarification on threshold-based reporting","source":"SA WG2","contact":"Zhuoyun Zhang","contact-id":106952,"tdoctype":"LS out","for":"Approval","abstract":"To: CT WG3. Attachments: TS 23.501 CR6341","secretary_remarks":"Revision of S2-2509421, merging S2-2508801, S2-2508631 and S2-2508425.  Agreed in parallel session. Block approved","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":12970,"status":"approved","reservation_date":"2025-10-20 13:06:55","uploaded":"2025-10-20 16:11:09","revisionof":"S2-2509421","revisedto":"","release":"Rel-19","crspec":"","crspecversion":"","workitem":[{"winame":"EnergySys"}],"crnumber":"","crrevision":"","crcategory":"","tsg_crp":"","lsreplyto":"S2-2508176","lsto":"CT WG3","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509467.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509647","title":"Clarification on handling of application ID\/predefined PDRs in reporting of usage data volume to EIF- option SMF is aware of App ID","source":"Nokia","contact":"Alessio Casati","contact-id":82456,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarify the solution assumes that the SMF can be Application ID semantics aware.","secretary_remarks":"Revision of S2-2509424. WITHDRAWN","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13160,"status":"withdrawn","reservation_date":"2025-10-20 13:08:09","uploaded":null,"revisionof":"S2-2509424","revisedto":"","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6438.0,"crrevision":3.0,"crcategory":"F","tsg_crp":"","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":"","me_affected":"","ran_affected":"","cn_affected":"","clauses_affected":"","crsinpack":null,"crsinpacknumber":0},
{"name":"S2-2509648","title":"Clarifications on energy consumption information for replaced PDU session","source":"Samsung","contact":"Dongeun Suh","contact-id":84836,"tdoctype":"CR","for":"Approval","abstract":"Summary of change: Clarifications on the SMF reporting to the EIF in case of the network slice replacement","secretary_remarks":"Revision of S2-2509425. This CR was agreed","agenda_item_sort_order":115,"ainumber":"19.4.2","ainame":"5GS Enhancement for Energy Efficiency and Energy Saving (EnergySys)","tdoc_agenda_sort_order":13230,"status":"agreed","reservation_date":"2025-10-20 13:08:11","uploaded":"2025-10-20 16:11:09","revisionof":"S2-2509425","revisedto":"","release":"Rel-19","crspec":"23.501","crspecversion":"19.5.0","workitem":[{"winame":"EnergySys"}],"crnumber":6435.0,"crrevision":3.0,"crcategory":"F","tsg_crp":"SP-251330","lsreplyto":"","lsto":"","Cc":"","lsoriginalls":"","lsreply":"","link":"https:\/\/www.3gpp.org\/ftp\/tsg_sa\/WG2_Arch\/TSGS2_171_Wuhan_2025-10\/Docs\/S2-2509648.zip","group":"S2","meeting":"S2-171","year":2025,"uicc_affected":false,"me_affected":false,"ran_affected":false,"cn_affected":true,"clauses_affected":"5.51.2.2.2","crsinpack":null,"crsinpacknumber":0}]